Troubleshooting; Specifications - Martin Magnum 1200 User Manual

Smoke machine
Hide thumbs Also See for Magnum 1200:
Table of Contents

Advertisement

Troubleshooting
Specifications
Problem
Probable cause(s)
Suggested remedy
Magnum 1200
Magnum 1800
Machine not at operating
Wait 1 o to 15 minutes
temperature
Physical
Machine will not produce fog
Machine not powered up or
Ensure mains power switch
when remote control Fog
on, enable heaters by
button pressed
heaters disabled
pressing FOG
Length ................................................................. 450mm ............................ soomm
Width ................................................................... 205mm ............................ 232mm
Height .................................................................. 244mm ............................ 266mm
Dry weight .............................................................. 8.2Kg ............................... 9.9Kg
Output level conlrol set to
lncrease setting
zero
Performance
Machine continues to
Disengage the timer by
produce fog when Fog
Timer is engaged
pressihg the FOG/TIMER
button is not pressed
ENGAGE button briefly
Effect coverage .............................................. 290m
3
/min ....................... 580m
3
/min
Operating time ............................................... continuous ....................... continuous
Warm up time .................................................. 8 minutes ....................... 10 minutes
Safety device ................................................. DTP device ...................... DTP device
Machine can be fired from
DMX address setting
Change DMX address (page
incorrect
13)
the remote control, but not
by DMX controller
Poor connection in DMX Iine
Check DMX cables and
connections
Control and programming
Control options .......................................... timer remote .......... DMX, timer remote
DMX channels ........................................................... n/a ....................................... 1
Smoke output is weak
Machine requires priming
Prime machine (page 14)
Fluid system
Wet, greasy, non-uniform
Capacity ............................................................... 2.3 litre ............................. 3.8 litre
smoke output, fluid drips or
Fluid consumption ........................................... 50ml/min .......................... 70ml/min
spits from nozzles, or
very
lncompatible smoke fluid
Use only approved fluid!
Compatible fluids ................................................... DJ,ZR. ........................ DJ,ZR,SP
loud noise when firing
machine
Connections
Mains fuse blown
Replace fuse (page 19)
Machine appears dead
No power at AC cable inlet
Check power cable and
circuit breaker
DMX ............................................................................ nja ......................... 3 pin XLR
Remote
1
machine link ........................................ RJ45
x2 ............................
RJ45
x2
AC power ......................................................... IEC plug .......................... .IEC plug
Electrical
AC voltage .................................... 120V /230V, 50/60Hz ...... 120V
1
230V, 50/60Hz
Main fuse (120V US version) .................................. 10AT ................................ 10AT
Main fuse (230V EU version) .................................... 5A
T.. .............................
6.3AT
Power usage (120V US version) ................. 890W (7.4A) ................... 1040W (8.6A)
Power usage (230V EU version) ................. 890W (3.9A) ................... 1190W (5.2A)
The following specifications apply to both machines:
Thermal
Maximum ambient temperature (Ta max) ............................................ 40°C (104°f)
Exterior surface temperature, steady state, at 20°C ambient .............. 40°C (104°F)
Approvals
European EMC: ....................................... EN61000-6-3,EN61000-3-2,EN61000-3-3
European safety: .................................................................. EN 60 335-1 ,EN50366
lmmunity: ............................................... EN61000-6-1, EN61000-4-2,EN61000-4-3
ETL approvals (cETLus) ................................................ UL60335-1, CSA-E60335-1
22
Troubleshooting
Specifications
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum 1800

Table of Contents