Carefree TRAVEL'RFIXED PITCH Service Manual page 37

Motorized patio awning
Table of Contents

Advertisement

Carefree of Colorado
O
W
VERRIDE
ITHOUT
This procedure does not apply if Direct Response is installed.
1.
Locate and separate the quick disconnects
located in the motor arm channel. Position
the wires from the motor on the outside of
the channel.
2.
Attach jumper wires to the motor wires.
3.
Connect the other ends of the jumper leads
to a 12-14V source. If the awning moves in
the wrong direction, reverse the leads.
4.
Maintain contact throughout the retraction
process. Hold the wires from the motor on
the outside of the channel while closing the
awning. This provides access for opening
awning.
5.
When power is restored, use the jumper
wires and extend the awning to access the
cable
disconnects.
disconnects and secure in the arm channel.
NOTE:
Jumper cables may not be included with some OEM installations.
Cables are available through your dealer
C
O
OMMON
PERATIONAL
The following items are operational items that may come up as questions during
normal operation.
1.
The awning motor is equipped with a thermal protection circuit to protect the motor
from overheating. Operating the awning repeatedly over a short time period may
cause the circuit to sense a overheat condition and shut off the motor. If this
occurs, wait approximately 15 minutes to allow the motor to cool then operate the
awning in normal fashion.
2.
The awning seems to extend and retract slowly. Normal operation time is 28-35
seconds to extend or retract. If the power supply is on the low side of the
acceptable voltage range (10VDC-14VDC) the awning will move slower.
3.
The awning may appear to move jerkily. When the fabric is rolled out, the
Alumaguard or Uniguard may "bounce" creating a wave like motion in the canopy
fabric. This will create the appearance of moving jerkily.
4.
With Uniguard, the awning sticks or hangs up. When Uniguard is installed with a
vinyl canopy, the vinyl will have a tendency to "cling" to the Uniguard when not
used over an extended period. Open and close the awning in short bursts 2 or 3
times, the awning will then open normally.
E
T
MERGENCY
ERMINALS
Reattach
Q
UESTIONS
Hold Wires
Outside of Channel
When Arm is Closing
Quick Disconnects
in Arm Channel
Motor
Cable
the
Awning
Closed
or
Jumper
Cable
TravelR061a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Travel'r adjustable pitch

Table of Contents