Confidential
3. When the electrical pulse to the drive coil ends, the dot wire and operation plate are
returned to the standby status by the spring force of the wire return spring and operation
plate spring. (See Figure D-6.)
Paper
Wire return spring
Operating plate
Dot wire
Wire guide
Ink ribbon
Platen
Core
Drive coil
Figure D-6