GE UR Series L90 Instruction Manual page 679

Line current differential system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 19 of 72)
ADDR
REGISTER NAME
3F06
Field Unit RTD 1 Origin
3F07
Field Unit RTD 1 Type
3F08
...Repeated for Field Unit RTD 2
3F10
...Repeated for Field Unit RTD 3
3F18
...Repeated for Field Unit RTD 4
3F20
...Repeated for Field Unit RTD 5
3F28
...Repeated for Field Unit RTD 6
3F30
...Repeated for Field Unit RTD 7
3F38
...Repeated for Field Unit RTD 8
Field Unit Transducers (Read/Write Setting) (8 modules)
3F40
Field Unit Transducer 1 Name
3F46
Field Unit Transducer 1 Origin
3F47
Field Unit Transducer 1 Range
3F48
Field Unit Transducer 1 Min Value
3F4A
Field Unit Transducer 1 Max Value
3F4C
Field Unit Transducer 1 Units
3F4F
...Repeated for Field Unit Transducer 2
3F5E
...Repeated for Field Unit Transducer 3
3F6D
...Repeated for Field Unit Transducer 4
3F7C
...Repeated for Field Unit Transducer 5
3F8B
...Repeated for Field Unit Transducer 6
3F9A
...Repeated for Field Unit Transducer 7
3FA9
...Repeated for Field Unit Transducer 8
Field Unit Identifiers (Read Only) (8 modules)
3FB8
Attached Field Unit 1 Serial Number
3FBE
Attached Filed Unit 1 Port Number
3FBF
Attached Field Unit 1 Type
3FC0
Field Unit 1 Status
3FC1
...Repeated for Field Unit 2
3FCA
...Repeated for Field Unit 3
3FD3
...Repeated for Field Unit 4
3FDC
...Repeated for Field Unit 5
3FE5
...Repeated for Field Unit 6
3FEE
...Repeated for Field Unit 7
3FF7
...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
400A
Setting Password Setting
Passwords (Read/Write)
4014
Command Password Entry
401E
Setting Password Entry
Passwords (Read Only)
4028
Command Password Status
4029
Setting Password Status
Passwords (Read/Write Setting)
402A
Command Password Access Timeout
402B
Setting Password Access Timeout
402C
Invalid Password Attempts
402D
Password Lockout Duration
Passwords (Read/Write)
402E
Password Access Events
GE Multilin
RANGE
0 to 1
0 to 2
0 to 1
0 to 24
0 to 9
-9999.999 to 9999.999
-9999.999 to 9999.999
---
---
---
0 to 3
0 to 4
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
5 to 480
5 to 480
2 to 5
5 to 60
0 to 1
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F205
---
1
F259
---
1
F205
---
1
F53
---
1
F246
---
0.01
F004
---
0.001
F004
---
---
F206
---
1
F205
---
1
F001
---
1
F243
---
1
F262
---
1
F202
---
1
F202
---
1
F202
---
1
F202
---
1
F102
---
1
F102
min
1
F001
min
1
F001
---
1
F001
min
1
F001
---
1
F102
DEFAULT
"RTD 1"
0 (100 Ohm
Nickel)
B
"TRD 1"
0 (none)
6 (0...20mA)
0
100000
(none)
(none)
0
0 (CC-05)
0 (Disabled)
0
0
(none)
(none)
0 (Disabled)
0 (Disabled)
5
30
3
5
0 (Disabled)
B-27