Table B–9: MODBUS MEMORY MAP (Sheet 31 of 72)
ADDR
REGISTER NAME
5E5B
...Repeated for Ground Instantaneous Overcurrent 12
CT Fail (Read/Write Setting) (6 modules)
5E6C
CT Fail 1 Function
5E6D
CT Fail 1 Block
5E6F
CT Fail 1 Current Source 1
5E70
CT Fail 1 Current Pickup 1
5E71
CT Fail 1 Current Source 2
5E72
CT Fail 1 Current Pickup 2
5E73
CT Fail 1 Voltage Source
5E74
CT Fail 1 Voltage Pickup
5E75
CT Fail 1 Pickup Delay
5E76
CT Fail 1 Target
5E77
CT Fail 1 Events
5E78
...Repeated for CT Fail 2
5E84
...Repeated for CT Fail 3
5E90
...Repeated for CT Fail 4
5E9C
...Repeated for CT Fail 5
5EA8
...Repeated for CT Fail 6
87L Trip Logic (Read/Write Grouped Setting)
5EE0
87L Trip Function
5EE1
87L Trip Source
5EE2
87L Trip Mode
5EE3
87L Trip Supervision
5EE5
87L Trip Force 3 Phase
5EE7
87L Trip Seal In
5EE8
87L Trip Seal In Pickup
5EE9
87L Trip Target
5EEA
87L Trip Events
Stub Bus (Read/Write Grouped Setting)
5F10
Stub Bus Function
5F11
Stub Bus Disconnect
5F13
Stub Bus Trigger
5F15
Stub Bus Target
5F17
Stub Bus Events
50DD Disturbance Detection (Read/Write Grouped Setting)
5F20
50DD Function
5F21
50DD Non Current Supervision
5F23
50DD Control Logic
5F25
50DD Logic Seal In
5F27
50DD Events
Setting Groups (Read/Write Setting)
5F70
Setting Group for Modbus Comms (0 means group 1)
5F71
Setting Groups Block
5F73
FlexLogic to Activate Groups 2 through 6 (5 items)
5F7D
Setting Group Function
5F7E
Setting Group Events
Setting Groups (Read Only)
5F7F
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
GE Multilin
RANGE
0 to 1
0 to 4294967295
0 to 5
0 to 2
0 to 5
0 to 2
0 to 5
0 to 2
0 to 65.535
0 to 2
0 to 1
0 to 1
0 to 5
0 to 1
0 to 4294967295
0 to 4294967295
0 to 1
0.2 to 0.8
0 to 2
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 5
---
---
---
---
---
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F300
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.01
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F102
---
1
F167
---
1
F157
---
1
F300
---
1
F300
---
1
F102
pu
0.01
F001
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
DEFAULT
0 (Disabled)
0
0 (SRC 1)
B
2
1 (SRC 2)
2
0 (SRC 1)
20
1000
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
0 (3-Pole)
0
0
0 (Disabled)
20
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
0
0 (Disabled)
0
0
0
0 (Disabled)
0 (Disabled)
0
(none)
(none)
(none)
(none)
(none)
B-39