GE UR Series L90 Instruction Manual page 731

Line current differential system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 71 of 72)
ADDR
REGISTER NAME
E2B0
...Repeated for PMU Aggregator 4
Phasor Measurement Unit Recording Command (Read/Write Command)
E4D4
PMU 1 Recording Clear Command
E4D5
PMU 1 Recording Force Trigger
Phasor Measurement Unit Recording (Read/Write Setting)
E4DC
PMU 1 Record Function
E4DD
PMU 1 No Of Timed Records
E4DE
PMU 1 Trigger Mode
E4DF
PMU 1 Timed Trigger Position
Phasor Measurement Unit Control Block (Read/Write Setting) (4 modules)
E650
PMU Aggregator 1 Control Block SvEna
E652
PMU Aggregator 1 Control Block Client Control
E654
PMU Aggregator 1 CB SvEna Default
E656
PMU Aggregator 1 Control Block ConfRev
E658
PMU Aggregator 1 Control Block Priority
E659
PMU Aggregator 1 Control Block IPClass
E65A
PMU Aggregator 1 Control Block VID
E65B
PMU Aggregator 1 Control Block APPID
E65C
PMU Aggregator 1 Control Block IP Address
E65E
PMU Aggregator 1 Control Block Security
E65F
...Repeated for PMU Aggregator 2
E66E
...Repeated for PMU Aggregator 3
E67D
...Repeated for PMU Aggregator 4
DNP/IEC Points (Read/Write Setting)
E700
DNP/IEC 60870-5-104 Binary Input Points (256 items)
E900
DNP/IEC 60870-5-104 Analog Input Points (256 items)
Synchrocheck (Read/Write Setting) (4 modules)
EC00
Synchrocheck 1 Function
EC01
Synchrocheck 1 V1 Source
EC02
Synchrocheck 1 V2 Source
EC03
Synchrocheck 1 Maximum Voltage Difference
EC05
Synchrocheck 1 Maximum Angle Difference
EC06
Synchrocheck 1 Maximum Frequency Difference
EC07
Synchrocheck 1 Dead Source Select
EC08
Synchrocheck 1 Dead V1 Maximum Voltage
EC09
Synchrocheck 1 Dead V2 Maximum Voltage
EC0A
Synchrocheck 1 Live V1 Minimum Voltage
EC0B
Synchrocheck 1 Live V2 Minimum Voltage
EC0C
Synchrocheck 1 Target
EC0D
Synchrocheck 1 Events
EC0E
Synchrocheck 1 Block
EC10
Synchrocheck 1 Frequency Hysteresis
EC11
...Repeated for Synchrocheck 2
EC22
...Repeated for Synchrocheck 3
EC33
...Repeated for Synchrocheck 4
Phasor Measurement Unit Frequency Trigger (Read/Write Setting) (4 modules)
ECCC
PMU 1 Frequency Trigger Function
ECCD
PMU 1 Frequency Trigger Low Frequency
ECCE
PMU 1 Frequency Trigger High Frequency
ECCF
PMU 1 Frequency Trigger Pickup Time
ECD0
PMU 1 Frequency Trigger Dropout Time
ECD1
PMU 1 Frequency Trigger Block (3 items)
ECD7
PMU 1 Frequency Trigger Target
GE Multilin
Table B–9: MODBUS MEMORY MAP (Sheet 72 of 72)
RANGE
ADDR
ECD8
Setting file template values (read only)
0 to 1
ED00
0 to 1
ED01
ED07
0 to 1
ED09
2 to 128
Phasor Measurement Unit Records (Read Only)
0 to 1
EFFF
1 to 50
0 to 4294967295
0 to 4294967295
0 to 4294967295
1 to 4294967295
0 to 7
0 to 1
0 to 4095
0 to 16383
0 to 4294967295
0 to 2
0 to 4294967295
0 to 65535
0 to 1
0 to 5
0 to 5
0 to 400000
0 to 100
0 to 2
0 to 5
0 to 1.25
0 to 1.25
0 to 1.25
0 to 1.25
0 to 2
0 to 1
0 to 4294967295
0 to 0.1
0 to 1
20 to 70
20 to 70
0 to 600
0 to 600
0 to 4294967295
0 to 2
L90 Line Current Differential System
B.4 MEMORY MAPPING
REGISTER NAME
UNITS
STEP
FORMAT
PMU 1 Frequency Trigger Events
FlexLogic displays active
---
1
F126
Undefined
---
1
F126
Last settings change date
Template bitmask (750 items)
---
1
F102
---
1
F001
PMU Recording Number of Triggers
---
1
F542
%
1
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F003
---
1
F001
---
1
F563
---
1
F001
---
1
F001
---
1
F003
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F167
---
1
F167
V
1
F060
degrees
1
F001
Hz
0.01
F001
---
1
F176
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
pu
0.01
F001
---
1
F109
---
1
F102
---
1
F300
Hz
0.01
F001
---
1
F102
Hz
0.01
F001
Hz
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
DEFAULT
RANGE
0 to 1
0 (No)
0 to 1
0 (No)
---
0 to 429496729
B
0 (Disabled)
0 to 65535
3
0 (Auto
0 to 65535
Overwrite)
10
0
0
0
1
4
1 (Expedited
Forwarding)
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
1 (SRC 2)
10000
30
100
1 (LV1 and DV2)
30
30
70
70
0 (Self-reset)
0 (Disabled)
0
6
0 (Disabled)
4900
6100
10
100
0
0 (Self-reset)
B-79