GE UR Series L90 Instruction Manual page 698

Line current differential system
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 38 of 72)
ADDR
REGISTER NAME
701B
...Repeated for Phase Undervoltage 2
701C
...Repeated for Phase Undervoltage 2
7022
...Repeated for Phase Undervoltage 3
7025
...Repeated for Phase Undervoltage 3
7027
...Repeated for Phase Undervoltage 3
B
7028
...Repeated for Phase Undervoltage 3
702A
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
7047
Phase Overvoltage 1 Target
7048
Phase Overvoltage 1 Events
7049
Reserved (8 items)
Distance (Read/Write Grouped Setting)
7060
Distance Signal Source
7061
Memory Duration
7062
Force Self-Polarization
7064
Force Memory Polarization
Phase Distance (Read/Write Grouped Setting) (5 modules)
7070
Phase Distance Zone 1 Function
7071
Phase Distance Zone 1 Current Supervision
7072
Phase Distance Zone 1 Reach
7073
Phase Distance Zone 1 Direction
7074
Phase Distance Zone 1 Comparator Limit
7075
Phase Distance Zone 1 Delay
7076
Phase Distance Zone 1 Block
7078
Phase Distance Zone 1 Target
7079
Phase Distance Zone 1 Events
707A
Phase Distance Zone 1 Shape
707B
Phase Distance Zone 1 RCA
707C
Phase Distance Zone 1 DIR RCA
707D
Phase Distance Zone 1 DIR Comp Limit
707E
Phase Distance Zone 1 Quad Right Blinder
707F
Phase Distance Zone 1 Quad Right Blinder RCA
7080
Phase Distance Zone 1 Quad Left Blinder
7081
Phase Distance Zone 1 Quad Left Blinder RCA
7082
Phase Distance Zone 1 Volt Limit
7083
Phase Distance Zone 1 Transformer Voltage Connection
7084
Phase Distance Zone 1 Transformer Current Connection
7085
Phase Distance Zone 1 Rev Reach
7086
Phase Distance Zone 1 Rev Reach RCA
7087
Reserved (10 items)
7091
...Repeated for Phase Distance Zone 2
70B2
...Repeated for Phase Distance Zone 3
70D3
...Repeated for Phase Distance Zone 4
70F4
...Repeated for Phase Distance Zone 5
7139
Ground Distance Zone 1 Events
713A
Ground Distance Zone 1 Shape
713B
Ground Distance Zone 1 Z0 Z1 Magnitude
713C
Ground Distance Zone 1 Z0 Z1 Angle
B-46
RANGE
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
5 to 25
0 to 4294967295
0 to 4294967295
0 to 1
0.05 to 30
0.02 to 500
0 to 2
30 to 90
0 to 65.535
0 to 4294967295
0 to 2
0 to
0 to 1
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 5
0 to 12
0 to 12
0.02 to 500
30 to 90
---
0 to 1
0 to 1
0 to 10
-90 to 90
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
cycles
1
F001
---
1
F300
---
1
F300
---
1
F102
pu
0.001
F001
ohms
0.01
F001
---
1
F154
degrees
1
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F120
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
pu
0.001
F001
---
1
F153
---
1
F153
ohms
0.01
F001
degrees
1
F001
---
---
F001
---
1
F102
---
1
F120
---
0.01
F001
degrees
1
F002
DEFAULT
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
10
0
0
0 (Disabled)
200
200
0 (Forward)
90
0
0
0 (Self-reset)
0 (Disabled)
0 (Mho)
85
85
90
1000
85
1000
85
0
0 (None)
0 (None)
200
85
0
0 (Disabled)
0 (Mho)
270
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents