APPENDIX B
F124
ENUMERATION: LIST OF ELEMENTS
bitmask
element
0
Phase Instantaneous Overcurrent 1
1
Phase Instantaneous Overcurrent 2
2
Phase Instantaneous Overcurrent 3
3
Phase Instantaneous Overcurrent 4
4
Phase Instantaneous Overcurrent 5
5
Phase Instantaneous Overcurrent 6
6
Phase Instantaneous Overcurrent 7
7
Phase Instantaneous Overcurrent 8
8
Phase Instantaneous Overcurrent 9
9
Phase Instantaneous Overcurrent 10
10
Phase Instantaneous Overcurrent 11
11
Phase Instantaneous Overcurrent 12
16
Phase Time Overcurrent 1
17
Phase Time Overcurrent 2
18
Phase Time Overcurrent 3
19
Phase Time Overcurrent 4
20
Phase Time Overcurrent 5
21
Phase Time Overcurrent 6
24
Phase Directional Overcurrent 1
25
Phase Directional Overcurrent 2
32
Neutral Instantaneous Overcurrent 1
33
Neutral Instantaneous Overcurrent 2
34
Neutral Instantaneous Overcurrent 3
35
Neutral Instantaneous Overcurrent 4
36
Neutral Instantaneous Overcurrent 5
37
Neutral Instantaneous Overcurrent 6
38
Neutral Instantaneous Overcurrent 7
39
Neutral Instantaneous Overcurrent 8
40
Neutral Instantaneous Overcurrent 9
41
Neutral Instantaneous Overcurrent 10
42
Neutral Instantaneous Overcurrent 11
43
Neutral Instantaneous Overcurrent 12
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
50
Neutral Time Overcurrent 3
51
Neutral Time Overcurrent 4
52
Neutral Time Overcurrent 5
53
Neutral Time Overcurrent 6
56
Neutral Directional Overcurrent 1
57
Neutral Directional Overcurrent 2
60
Negative Sequence Directional Overcurrent 1
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
66
Ground Instantaneous Overcurrent 3
67
Ground Instantaneous Overcurrent 4
68
Ground Instantaneous Overcurrent 5
69
Ground Instantaneous Overcurrent 6
70
Ground Instantaneous Overcurrent 7
GE Multilin
bitmask
71
72
73
74
75
80
81
82
83
84
85
86
87
88
89
90
91
96
97
101
112
113
120
121
122
140
144
145
148
152
154
156
160
161
162
163
164
168
172
173
174
175
176
180
185
190
214
215
224
225
226
227
228
L90 Line Current Differential System
B.4 MEMORY MAPPING
element
Ground Instantaneous Overcurrent 8
Ground Instantaneous Overcurrent 9
Ground Instantaneous Overcurrent 10
Ground Instantaneous Overcurrent 11
Ground Instantaneous Overcurrent 12
Ground Time Overcurrent 1
Ground Time Overcurrent 2
Ground Time Overcurrent 3
Ground Time Overcurrent 4
Ground Time Overcurrent 5
Ground Time Overcurrent 6
Restricted Ground Fault 1
Restricted Ground Fault 2
Restricted Ground Fault 3
Restricted Ground Fault 4
Restricted Ground Fault 5
Restricted Ground Fault 6
Negative Sequence Instantaneous Overcurrent 1
Negative Sequence Instantaneous Overcurrent 2
Opposite Phase Rotation
Negative Sequence Time Overcurrent 1
Negative Sequence Time Overcurrent 2
Negative Sequence Overvoltage
Wattmetric Zero-Sequence Directional 1
Wattmetric Zero-Sequence Directional 2
Auxiliary Undervoltage 1
Phase Undervoltage 1
Phase Undervoltage 2
Auxiliary Overvoltage 1
Phase Overvoltage 1
Compensated Overvoltage 1
Neutral Overvoltage 1
Phase Distance Zone 1
Phase Distance Zone 2
Phase Distance Zone 3
Phase Distance Zone 4
Phase Distance Zone 5
Line Pickup
Ground Distance Zone 1
Ground Distance Zone 2
Ground Distance Zone 3
Ground Distance Zone 4
Ground Distance Zone 5
Load Encroachment
PUTT Pilot Scheme
Power Swing Detect
Sensitive Directional Power 1
Sensitive Directional Power 2
SRC1 VT Fuse Failure
SRC2 VT Fuse Failure
SRC3 VT Fuse Failure
SRC4 VT Fuse Failure
SRC5 VT Fuse Failure
B