EMERGENCY PROCEDURES
Engine Inoperative Procedures
(1)
Air Conditioning Switch - OFF or VENTILATE.
FIRE DETECTION AND EXTINGUISHING SYSTEM
The fire detection and extinguishing system consists of
three major components: three heat sensitive detectors lo-
cated in each engine accessory compartment; an annunciator
and actuator panel (see Figure 7-4); and a compressed Freon
single shot gas bottle in each engine accessory compartment.
A test function is provided to test the system circuit-
ry.
When the test switch is pushed all lights should illu-
minate, if any light fails to illuminate replace the bulb.
If the green light does not illuminate after replacing the
bulb, replace firing cartridge in fire extinguisher.
Any
other light failure, after replacing bulbs and firing cart-
ridge, indicates malfunction in unit or associated wiring.
Annunciation
Cause of
Legend
Color
Illumination
Fire
Red
Fire condition
existing in
engine compart-
ment
E
Amber
Fire extinguish-
er container
empty
OK
Green
Fire cartridge
and associated
wiring is in
operational
condition
Figure 7-4