Oxygen System Servicing - Cessna 310 1975 Owner's Manual

Table of Contents

Advertisement

(1)
Mask - Connect mask and hose assembly and put mask
on.
(2)
Hose Coupling - Plug into overhead console.
(3)
Oxygen Flow Indicator - Check Flow.
(Indicator
toward mask indicates proper flow.)
(4)
Disconnect hose coupling from console when not in
use.
AMBIENT
FILLING
AMBIENT
FILLING
TEMPERATURE
PRESSURE
TEMPERATURE
PRESSURE
Of
PSIG
Of
PSIG
0
1600
70
1925
10
1650
80
1950
20
1675
90
2000
30
1725
100
2050
40
1775
110
2100
50
1825
120
2150
60
1875
130
2200
Example -
If
ambient temperature is 70°F, fill oxygen
cylinder to approximately 1925 psig - as close to
this pressure as the gage can be read.
Upon cooling,
the cylinder should have
approxim~tely
1800 psi
pressure.
Figure 7-2
OXYGEN SYSTEM SERVICING
The oxygen cylinder, when fully charged, contains 48.3
or 76.6 cubic feet of oxygen, under a pressure of 1800 psi at
70°F.
Filling pressures will vary, however, due to the
ambient temperature in the filling area, and because of the
temperature rise resulting from compression of the oxygen.
Because of this, merely filling to 1800 psi will not result
in a properly filled cylinder.
Fill to the pressures indi-
cated in Figure 7-2 for the ambient temperature.
7-6