5.3.3 Zoom adjustment

FBS zoom adjustment (Vertical)
A
L
R
Zoom ratio
Standard
Adjustment Tool
Setting Range
– 1.27 to 1.27 %
100 %
± 1.0 %
Machine parameter:042
(0.01 % step)
1. Load Letter size paper to the first cassette.
2. Place a Test Chart on the document glass.
3. Make two copies on paper in the first cassette with 100 % magnification.
4. Measure the length of A on the second copy to find the difference.
If length A falls outside the specified range, perform the following steps to make the adjustment.
5. Enter Machine Parameter mode. (See "3.2.1 Setting the machine parameters" on page 3-3.)
6. Adjust so that the setting of Machine Parameter 042 meets the specification.
If length A is shorter than the standard, increase value.
If length A is longer than the standard, decrease value.