4.6.5 Dark image density
Scanner section
Section
Step Check item
Scanner section 1
2
3
4
5
Printer section
Section
Step Check item
Drum cartridge 1
2
Circuit boards
3
4
Are the ADF glass and document
glass dirty?
Are the CIS (lens and lamp) and
document glass dirty?
Is the CIS installed properly?
Do the connection from CIS to main
control board remain intact?
Is the trouble settled with above
steps?
Are the developing bias, supply bias
and blade bias contact terminal dirty
or deformed?
Are the grid bias, charge bias and
drum ground contact terminal dirty or
deformed?
Are the connections from LED print
head and from high-voltage board to
main control board in good condition?
(Check plugs firmly plugged and
snapped harness.)
Is the trouble settled with above
steps?
Result Remedy
Yes
Clean
Yes
Clean
No
Install it properly
No
Reconnect / Replace harness.
No
1. Adjust the background level.
2. Replace CIS.
3. Replace main control board.
Result Remedy
Yes
Clean / Repair
Yes
Clean / Repair
No
Reconnect / Replace harness
No
1. Replace drum cartridge.
2. Replace LED print head.
3. Replace main control board.
4. Replace high-voltage power
board.