CABLE-ASSY SPEAKER

1. Remove the Cover platen. (See "COVER PLATEN" on page 5-23.)
2. Remove the Cover top FBS. (See "CIS" on page 5-27.)
3. Remove the PCB panel assy. (See "PCB PANEL ASSY (MFX-3535)" on page 5-30.)
4. Remove the PCB PANEL. (See "PCB PANEL (MFX-3535)" on page 5-32.)
5. Remove two screws [1].
6. Remove the CABLE-ASSY SPEAKER [2].
Important
When you reattach the speaker, be sure that a "" inscription is at the direction where the harness is.