4.6.4 Low image density / rough image
Scanner section
Section
Step Check item
Scanner section 1
2
3
4
Printer section
Section
Step Check item
Paper
1
LED print head 2
Drum cartridge 3
4
Transfer section 5
6
Circuit boards
7
Toner sensor er-
8
ror
9
Do the connection from CIS to main
control board remain intact?
Are the document glass, document
pad and ADF glass dirty?
Is the CIS lens dirty?
Is the trouble settled with above
steps?
Is the paper damp?
Is the lens dirty?
Are the developing bias, supply bias
and blade bias contact terminal dirty
or deformed?
Are the grid bias, charge bias and
drum ground contact terminal dirty or
deformed?
Is the transfer bias contact terminal
dirty or deformed?
Is the transfer roller gap dirty?
Are the connections from LED print
head and from high-voltage board to
main control board in good condition?
(Check plugs firmly plugged and
snapped harness.)
Is the toner sensor working?
(Use "3.20 Sensor input test" on page
3-103 and check that the sensor is
working.)
Is the trouble settled with above
steps?
Result Remedy
No
Reconnect / Replace harness.
Yes
Clean
Yes
Clean, or replace the part and
adjust the background level
No
1. Adjust the background level.
2. Replace CIS.
3. Replace main control board.
Result Remedy
Yes
Replace the paper.
Yes
Clean
Yes
Clean / Repair
Yes
Clean / Repair
Yes
Clean / Replace
Yes
Clean / Replace
No
Reconnect / Replace harness
No
Reconnect / Replace sensor
No
1. Replace drum cartridge.
2. Replace LED print head.
3. Replace main control board.
4. Replace high-voltage power
board.
5. Replace transfer roller unit.
4-25