Chapter 4. Operations
If you specify and select
this will
«
this field on
this option happen
menu 2
AUTO LF
ON"
Moves the cursor to the first character position of the next line when
the carriage return (CR) key is pressed or the CR control character is
received from the host system.
OFF
Moves the cursor to the first character position of the current line.
Therefore, if the new line function is desired, the host system must
send the CR and LF control characters or they must be entered from
the keyboard.
SEND
PAGE~
The content of the current page is sent to the host system when the
Send key is pressed . The content of the current cursor line is sent to
the host when the Send Line key is pressed.
LINE
The content of the current cursor line is sent to the host system when
the Send key is pressed. The content of the current page is sent to
the host when the Send Line key is pressed.
SEND NULL
OFF
Trailing nulls are replaced with space characters and sent to the host
system.
ON*
Trailing nulls are not sent to the host system.
INSERT
MODE*
The terminal enters insert mode when the Insert key is pressed.
SPACE
A blank is inserted when the Insert key is pressed.
TRACE
ALL*
Both the inbound data (data to the host system) and outbound data
(data from the host system) of the main port are transferred to the
auxiliary port without disturbing the communication with the host
when the Trace key is pressed.
RECEIVE
Only the outbound data (data from the host system) of the main port
(
is transferred to the auxiliary port without disturbing the
communication with the host when the Trace key is pressed.
SEND
Only the inbound data (data to the host system) of the main port is
transferred to the auxiliary port \rAv'ithout disturbing the communication
with the host when the Trace key is pressed.
CRT SAVER
NO*
Disables this function.
5
The screen goes blank if there is no activity (no host or operator
input) on the terminal for 5 mtnutes. When data is received from the
host system or if a key is pressed, the cathode-ray tube (CRT)
contents are displayed again without loss of previously input data.
10
The screen goes blank if there is no activity (no host or operator
input) on the terminal for 10 minutes. When data is received from the
host system or if a key is pressed, the cathode ray tube (CRT)
I
contents are displayed again without loss of previously input data.
15
The screen goes blank if there is no activity (no host or operator
input) on the terminal for 15 minutes. When data is received from the
host system or if a key is pressed, the cathode-ray tube (CRT)
contents are displayed again without loss of previously input data.
Note:
An asterisk (*) indicates a default value.