IBM 3164 ASCII Manual page 197

Color display station
Table of Contents

Advertisement

You can emulate the following IBM 3101
by
using the following IBM 3164
c
Model 23 setup switch functions
functions in emulation mode
BLOCK/CHAR switch (position 1 in group 1).
Setup menu (selectable from BLOCK, CHAR,
and ECHO mode on the Operating Mode field).
H OX/FOX switch (position 2 in group 1).
Setup menu (automatically selected when the
operating mode is selected).
Interface switch (position 3 in group 1).
Setup menu (selectable between RS-232C and
RS-422A on the Interface field).
PRTS/CRTS switch (position 4 in group 1).
Setup menu (selectable from PRTS, CRTS, and
I PRTS on the Line Control field).
REVERSE CH switch (position 5 in group 1).
This condition is not available.
Turnaround Character switches (positions 6 and
Setup menu (selectable from ETX, CR, EOT, and
7 in group 1).
DC3 on the Turnaround Character field).
DUAL/MONO switch (position 8 in group 1).
This condition is not available.
Stop 1 /Stop 2 switch (position 1 in group 2).
Setup menu (selectable between 1 and 2 on the
Stop Bit field).
Parity Bit Selection switches (positions 2 and 3
Setup menu (selectable from ODD, NO, SPACE,
in group 2).
MAR K, and EVEN on the Parity field).
Send Line Option switch (position 4 in group
Select menu (selectable between PAGE and
2) .
LI NEon the Send field).
NULL SUPP switch (position 6 in group 2).
Select menu (selectable between ON and OFF
on the Null Supp field).
Time- Fill switches (positions 7 and 8 in group
This condition is not available.
2) .
(
AUTO N L switch (position 1 in group 3).
Select menu (selectable between ON and OFF
on the Line Wrap field).
AUTO LF switch (position 2 in group 3).
Select menu (selectable between ON and OFF
on the Auto LF field).
CR/CR.LF switch (position 3 in group 3).
Select menu (selectable between CR-LF and
CR on the Return field).
SCROLL switch (position 4 in group 3).
Select menu (selectable between ON and OFF
on the Scroll field. SMOOTH can be selected
but does not work on the IBM 3101.)
REVERSE VIDEO switch (position 7 in group
This condition is not available.
3) .
Blink Cursor switch (position 8 in group 3).
This condition is available on the Alt Csr key.
Line speed switches for telecommunication
Setup menu (selectable from 50, 75, 11O,
interface (positions 1 to 4 in group 4).
134.5,150,200,300,600,1200,1800,2400,
3600, 4800, 7200, 9600, and 19200 bps on the
Line Speed field).
Line speed switches for auxiliary interface
Setup menu (selectable from 50, 75, 11O,
(positions 5 to 8 in group 4).
134.5,150,200,300,600,1200,1800,2400,
3600, 4800, 7200, 9600, and 19200 bps on the
Line Speed field).
E-4

Advertisement

Table of Contents
loading

Table of Contents