New Project

Copy Project
Rename Project
Delete Project
Clear Project Data
New project
Press the Menu button and select the New Project item. Enter the name of the project. The new project is
added to the list of projects and it is selected (active in dark colour). Press OK (F3) to open the project. The list
of settings appears. Define your balancer settings and press OK (F3).

Project menu

Balancer Settings

All project properties are defined here as follows:
Planes
single, dual
Point A
1-3
Point B
1-3
Note: The point markings A and B have only a symbolic sense. They have no relation to the
balancing planes 1 and 2 and to the balancing computational procedure. You can mark any
measuring point as A and the second as B.
Remove Trial yes, no
trial mass is kept on the rotor, then it must be included into the final mass calculation.
Balancing Masses
Blades
the number of blades (for rotors with blades). This parameter is used in calculations to split the
mass between blades.
Meas Mode
single, online meter
be taken (single) or the continual measurement values displayed (online meter). In the online
meter mode you can look at more values and evaluate their changes over time. When the value
which you want to use is displayed, you need to STOP the measurement.
Avg
the averaging of more then one measured value is available
Resolution
read the explanation in the Analyzer mode chapter: Meas functions/ New Advanced section.
For further technical and contact information visit www.adash.com, email: info@adash.cz
when you select the New Project item, you have to enter the name of the new project.
creates the new project as a copy of the selected project. Only Balancer Settings are
saved. No measured data are saved.
renames the selected project.
deletes the selected project.
erases all measured data, only the Project with Balancer Settings remains in unit.
plane(s) balancing
the number of the AC input which will be used for the sensor mounted on point A
the number of the AC input which will be used for the sensor mounted on point B
the trial masses can be left on the rotor or removed after the trial run. When the
add (mount) / remove (drill)
when you press the Start button, then only one measurement value can
48