Wiring Schematic; Wire And Cable Specifications - Panasonic VL-MN1000 Installation And Operating Instructions Manual

Video intercom system - room monitor
Table of Contents

Advertisement

12. Installation

12.9 Wiring schematic

Door station
DC-IN
24 V
R2R1
LAN
B
RELAY BOX
Power
supply
Electric
lock
LAN cable
If the switching hub does not support PoE, a power supply unit (VL-PS240; sold separately) is required.
When connecting an electric lock (user supplied), a relay box (VL-RLY1; sold separately) is required.

12.10 Wire and cable specifications

Wiring run
Room monitor
Power supply unit
Power supply unit
12-pin terminal
connector
Note the following when selecting wiring
R For all wiring (except network wiring), use 2-conductor (solid copper) wiring with a PE (polyethylene)-insulated
PVC jacket.
Mid-capacitance, non-shielded wiring is recommended.
R A certified power supply wiring has to be used with this equipment. The relevant national installation and/or
equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl
chloride flexible wiring according to IEC 60227 shall be used.
38
24 V DC
To AC
POWER
power outlet
SUPPLY
UNIT
A
12 V AC/DC
Switching hub
«
Switching hub
«
Room monitor
«
AC power source
«
External device
Room monitor
Connection device for option input (A contact)
DC-IN
24 V
LAN
LAN cable
Specifications
Cat-5e or higher, stranded,
twisted pair, straight
0.65 mm (22 AWG)
2 mm (12 AWG)
1.2 mm (17 AWG)
2 mm (12 AWG)
0.5 mm (24 AWG)
1.2 mm (17 AWG)
24 V DC
To AC
POWER
power outlet
SUPPLY
UNIT
A
Max. length
100 m
approx. 10 m
approx. 20 m
No requirement
According to specification
of connected device.