12.3 Installation cautions

Refer to the information found in 2 Important information
(Page 4) before installing the product.
CAUTION
R If the wiring passes outdoors, use a conduit and a
surge protector.
R If the wiring passes underground, use a conduit, and
do not make any connections underground.
R Install the product securely adhering to the
instructions in this document to prevent it from falling
off the wall. Avoid installing onto low-strength walls,
such as gypsum board, ALC (autoclaved lightweight
concrete), concrete block, or veneer (less than
18 mm thick) walls.
12.4 Information about power
connection
There are 2 methods for powering the room monitor.
Choose one or the other; do not use both methods.
– Using Power over Ethernet (PoE)
In this case, the room monitor and a PoE-compatible
device (such as a PoE switching hub or a PoE power
supply) are connected by a single LAN cable. The
LAN cable carries both power and data.
– Using the VL-PS240 power supply unit (sold
separately)
In this case, the power supply unit is hardwired to the
power source, and connects to the room monitor
using the included DC plug.
12.5 Power over Ethernet (PoE)
connection
To power the room monitor using PoE, use a LAN cable
to connect the room monitor and a PoE-compatible
device (such as a PoE switch or power supply). See
12.10 Wire and cable specifications (Page 38) for LAN
cable specifications.
12.6 Installing the power supply
unit (sold separately)
If the room monitor will not be powered via PoE, you must
install a power supply unit.
Required items
– Power supply unit (VL-PS240; sold separately)
– DC plug (included)
– Cable binders (included with power supply unit)
– Screws (included with power supply unit)
– Wires for AC and DC connection (user supplied)
See 12.10 Wire and cable specifications
(Page 38) for specifications.
– Soldering gun and solder, insulation sleeve (user
supplied)
Installation location
R The device must be installed inside an electrical
panel or cabinet.
R A readily accessible disconnect device shall be
incorporated external to the equipment.
The external disconnect device must be certified, and
have a creepage and clearance distance of 3 mm or
more.
Installation methods
The following 2 methods can be used for installing the
power supply unit.
– mounting on a DIN rail (user supplied)
– attaching directly to a wall