Mahr Millimar C 1200 Operating Instructions Manual

Mahr Millimar C 1200 Operating Instructions Manual

Compact length measuring instrument
Hide thumbs Also See for Millimar C 1200:
Table of Contents

Advertisement

Quick Links

Compact length measuring instrument
Millimar C 1200

Operating Instructions

Valid from firmware version 1.3
3723034
Mahr GmbH
Esslingen Standort
Reutlinger Str. 48, 73728 Esslingen, Germany
Tel. +49 711 9312-600, Fax +49 711 9312-756
mahr.es@mahr.de, www.mahr.de
1016

Advertisement

Table of Contents
loading

Summary of Contents for Mahr Millimar C 1200

  • Page 1: Operating Instructions

    Compact length measuring instrument Millimar C 1200 Operating Instructions Valid from firmware version 1.3 3723034 Mahr GmbH Esslingen Standort Reutlinger Str. 48, 73728 Esslingen, Germany Tel. +49 711 9312-600, Fax +49 711 9312-756 mahr.es@mahr.de, www.mahr.de 1016...
  • Page 2 Introduction Permitted uses The Millimar C 1200 is an electronic length measuring and evaluation instrument for use in production. An inductive probe can be connected. The operating, maintenance and repair information detailed in these operating instructions must be followed.
  • Page 3: Safety Information

    The test and measuring equipment, for which the Millimar is used, are subject to inspection equipment monitoring. For this reason, regular inspection equipment monitoring performed by either the user or Mahr Service must ensure compliance to the specified error limits for the test and measuring equipment.
  • Page 4 Do not use an electric marking tool. Disposal information Electronic equipment which was purchased from Mahr after March 23, 2006 can be returned to us. We will dispose of this equipment in an environmentally-friendly way in accordance with EU Directives 2012/19/EU WEEE (Waste Electrical and Electronic Equipment) and the German National - Electrical and Electronic Equipment Act, ElektroG.
  • Page 5 EU Declaration of Conformity This measuring instrument conforms to the applicable EU directives. A copy of the Declaration of Conformity can be requested from the following address: Mahr GmbH, Standort Esslingen, Reutlinger Str. 48, 73728 Esslingen, Germany, or can be downloaded from: www.mahr.de/de/Leistungen/Fertigungsmesstechnik/Produkte...
  • Page 6: Table Of Contents

    Switching OFF ................18 Measurement menu Selecting the master ............... 19 Selecting the nominal value ............20 Selecting the tolerance ..............21 Selecting the formula ..............23 Selecting the function ..............24 Selecting the factor ................. 25 Mahr GmbH • Millimar C1200...
  • Page 7 Interfaces: Opto RS232C, Digimatic, USB ........48 Data transmission parameters ............49 Technical data Compact length measuring instrument Millimar C1200 ....50 Compatible probes for Millimar C1200 ..........51 Spare parts Available spare parts ..............52 Mahr GmbH • Millimar C1200...
  • Page 8: Delivery And Connection

    Delivery and connection Unpacking Mahr GmbH • Millimar C1200...
  • Page 9: Scope Of Delivery

    Scope of delivery Mahr GmbH • Millimar C1200...
  • Page 10: Symbols

    – Reduce the resolution – Increase the resolution – Start data transmission – Scroll up – Scroll down – Scroll to the right – Scroll to the left – Confirm – Cancel – Exit menu Mahr GmbH • Millimar C1200...
  • Page 11 Data is been transferred FACTOR – Factor is not equal to 1 – Activated tolerance (MAX), (MIN), (MAX-MIN) – Dynamic measuring functions – Start dynamic measurement – Pause dynamic measurement – Stop dynamic measurement – Reset dynamic measurement Mahr GmbH • Millimar C1200...
  • Page 12: Operating Elements And Interfaces

    Operating elements and interfaces 1.4.1 Display and operating keys Display Operating keys Battery compartment 1.4.2 Interfaces Data output Probe input A Mains connection Mahr GmbH • Millimar C1200...
  • Page 13: Battery Compartment

    Close the battery compartment cover in reverse order. Battery compartment If connected to the mains power supply, the measuring instrument will automatically switch to mains power supply. The rechargeable batteries are not recharged during mains power operation. Mahr GmbH • Millimar C1200...
  • Page 14: Initial Operation (Basic Configuration)

    – Press to confirm Italiano Polski ü Setting the measurement unit Welcome! – Select the required measurement Please select the measurement unit: unit with q or p µm inch ü – Press to confirm ü Mahr GmbH • Millimar C1200...
  • Page 15: Selecting The Measuring Probe

    Dynamic measuring mode 2.5.2 In dynamic measuring mode (max, min, max-min) (MAX) -0.001 – Select required resolution -0.1 with u t – Change the scaling direction pressing and holding the Mahr GmbH • Millimar C1200...
  • Page 16: Connecting The Measuring Probe

    Chapter 8.2, page 47 Probe type Standard probe ü to cancel – Press to confirm or Ó Long probe the selection – Press the ON / OFF key to exit the ü Ó input menu. Mahr GmbH • Millimar C1200...
  • Page 17: Setting Up The Probe

    ü Ó adjust the scale ABSOLUTE ü – Press to confirm -0.001 -0.1 – Press the ON / OFF key to exit the input menu. ü ut tu Mahr GmbH • Millimar C1200...
  • Page 18: Switching Off

    -0.1 menu. – Exit the Input menu to switch off the measuring instrument. ut tu => The Analog display will appear on the screen – Press and hold the ON / OFF key >2 seconds. Mahr GmbH • Millimar C1200...
  • Page 19: Measurement Menu

    “0”. 0 0 . 0 0 0 0 ü – Press to confirm or Ó to cancel the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 20: Selecting The Nominal Value

    Press the Ó key for more than two seconds to reset the input to “0”. ü ü – Press to confirm or Ó to cancel Ó the selection – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 21: Selecting The Tolerance

    -0.5000 +0.5000 ü Ó ü – Press to confirm or Ó to cancel the selection Measurement Display Setup System Tolerance 0 . 5 0 0 0 Lower tolerance Nominal Higher tolerance -0.5000 +0.5000 ü Ó Mahr GmbH • Millimar C1200...
  • Page 22 . 5 0 0 0 Lower tolerance Nominal Higher tolerance ü -0.5000 +0.5000 – Press to confirm or Ó to cancel the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 23: Selecting The Formula

    Press q p to select +A / -A – Measurement Display Setup System Formula ü – Press to confirm or Ó to cancel the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 24: Selecting The Function

    Press q p to select the required Measurement Display Setup System Function Function Normal Max-Min ü – Press to confirm or Ó to cancel ü Ó the selection – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 25: Selecting The Factor

    System value. Factor . 0 0 0 0 ü – Press to confirm the value or Ó ü Ó to exit the menu – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 26: Display Menu

    Press q p to select the required Measurement Display Setup System Resolution Resolution 0.01 ü 0.001 – Press to confirm or Ó to cancel 0.0001 the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 27: Selecting The Display Style

    System Display style Display style Analog & Digital ü Digital – Press to confirm or Ó to cancel Analog the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 28: Selecting The Color Scheme

    Measurement Display Setup System Color scheme Color scheme Standard ü Inverted – Press to confirm or Ó to cancel the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 29: Centering The Display

    Nominal value nominal size. Tolerance ü – Press to confirm or Ó to cancel ü the selection Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 30: Setting The Brightness

    Press q p to select the required Measurement Display Setup System Brightness Brightness ü – Press to confirm or Ó to cancel the selection ü ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 31: Setup Menu

    Language Measurement Display Setup System Language ü – Press to confirm or Ó to cancel Deutsch English the selection Español Português ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 32: Selecting The Unit Of Measurement

    Press q p to select the required Measurement Display Setup System Unit Unit ü – Press to confirm or Ó to cancel µm inch the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 33: Selecting The Probe Type

    Measurement Display Setup System Probe type ü – Press to confirm or Ó to cancel Standard probe Long probe the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 34: Selecting Eco Mode

    Press q p to select the required mode Measurement Display Setup System ECO mode ü – Press to confirm or Ó to cancel the selection ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 35: System Menu

    Press the u t and t u keys to ABSOLUTE adjust the scale 0.001 -0.01 0.01 ü – Press to confirm ut tu Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 36: Customer Calibration

    If a customer-specific calibration is required, this can be completed in the menus described in the following. The calibration can be completed with the connected probe or alternatively with a factory standard (e.g. Mahr 1283 WN Factory Calibration, Order no. 5312833).
  • Page 37: 6.2.2 Executing A Probe Calibration

    - 0 0 . 0 0 0 value. Calibration Min Nominal value Calibration Max ü -1.000 1.000 – Press to confirm or Ó to cancel ü the selection Ó Mahr GmbH • Millimar C1200...
  • Page 38 Customer calibration Factory calibration => Probe calibration according to Factory settings the customer's specification is Keyboard-/ menu interlock Info complete and activated. ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 39: Conducting A Factory Standard Calibration

    0 0 1 . 0 0 0 value. Calibration Min Nominal value Calibration Max -1.000 1.000 ü ü – Press to confirm or Ó to cancel Ó the selection Mahr GmbH • Millimar C1200...
  • Page 40 Set probe to Calibration Max and Measurement Display Setup System accept Customer calibration Please set the probe at Calibration ü – Press to confirm and accept Calibration Min Nominal value Calibration Max -1.000 1.000 ü Ó Mahr GmbH • Millimar C1200...
  • Page 41 Absolute mode ü specification is complete and Customer calibration Factory calibration activated Factory settings Keyboard-/ menu interlock Info ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 42: Executing A Customer Calibration Reset

    Measurement Display Setup System the selection Absolute mode ü Customer calibration Factory calibration Factory settings Keyboard-/ menu interlock Info ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 43: Activating A Factory Calibration

    Measurement Display Setup System Absolute mode Customer calibration ü Factory calibration Factory settings Keyboard-/ menu interlock Info – Press the ON / OFF key to exit the ü input menu. Ó Mahr GmbH • Millimar C1200...
  • Page 44: Resetting To Factory Settings

    Press to confirm or Ó to cancel the selection ü Ó => The measuring instrument switches off automatically. All of the default settings must be entered again after the restart (see Initial operation, page 14). Mahr GmbH • Millimar C1200...
  • Page 45: Activating The Menu Lock

    Enable or Disable Measurement Display Setup System Absolute mode Customer calibration ü Factory calibration – Press to confirm the selection Factory settings select Disable to and press Ó ü Keyboard-/ menu interlock cancel. Info ü Ó Mahr GmbH • Millimar C1200...
  • Page 46 PIN wrong! – Enter correct pin again and -1.000 1.000 ü confirm by pressing ü => If you have forgotten the pin, you can request the master pin from the product management team at Mahr GmbH. Mahr GmbH • Millimar C1200...
  • Page 47: Requesting Firmware Version And Serial Number

    The firmware version and serial number are displayed Measurement Display Setup System Info Version 1.3 S/N: 268500992 – Press Ó to exit the menu ü Ó – Press the ON / OFF key to exit the input menu. Mahr GmbH • Millimar C1200...
  • Page 48: Description Of The Interfaces

    MarCom Standard Order no. 4102230 Interfaces: Opto RS232C, Digimatic, USB Duplex operation PC-side Power supply DTR = “High” level RTS = “Low” level 4 ms min. 5 ms max. 40 ms Mahr GmbH • Millimar C1200...
  • Page 49: Data Transmission Parameters

    Data transmission parameters Mahr GmbH • Millimar C1200...
  • Page 50: Technical Data

    Technical data Compact length measuring instrument Millimar C 1200 Order no. Mahr: 5312010 Product type: Millimar C 1200 Display: TFT color display, 4.3 inch, 480 (W) x 272(H) pixels Keypad: Membrane keypad, 1 million actuations Units: µm, mm, inch Range of digital display: ±1000 mm...
  • Page 51: Compatible Probes For Millimar C1200

    Compatible probes for Millimar C 1200 Standard probe Order no. 1301 5313010 1303 5313030 1304 K 5313049 1318 5313180 P1300MA 4400180 P1300MB 4400181 P2001M 5323040 P2004M 5323010 P2004MA 5323020 P2004MB 5323030 P2104MA 5324070 P2104MB 5324080 Long probe P2010M 5324010 P2010MA...
  • Page 52: Spare Parts

    Spare parts Available spare parts Item no. Order no. Contents Designation (P.U.) 4346361-E Screw top 4885431-E Battery compartment cover incl. clamping screw 4885417-E Plug-in housing feet 4885430-E Elastic buffer, black, self-adhesive Mahr GmbH • Millimar C1200...

Table of Contents