6. DIAG. TEST OPERATION
6.3.2
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
>
D I A G N O S T I C
< 2
>
P A R A M E T E R
Press the [PAUSE] key twice.
F E
E
D
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a
fast forward.
2. Max. fine adjustment – 50.0 mm = Key fine adjustment value ( – 50.0 mm) + PC fine
adjustment value ( – 50.0 mm)
When the value reaches the maximum, the value remains unchanged even if a subsequent
fine adjustment is performed.
3. A changed cut/strip position value is stored in memory by pressing the [PAUSE] key.
4. When using label with length of less than 38 mm, calculate the cut position fine adjustment
value using the expression provided on page 6-21.

Cut/Strip Position Fine Adjustment

Power off
Press the [FEED] key.
S E T
A D J U S T
+ 1 2
Press the [FEED] key
and [RESTART] key
at the same time.
1 . 0 A
V
. 0 m m
[FEED] key:
[RESTART] key: Pressing the [RESTART] key one
Press the [PAUSE] key.
Continued on Section 6.3.3
Back feed length fine adjustment.
6-18
6.3 PARAMETER SETTING MODE
Pressing the [FEED] key one
time is a -0.5 mm change, up to
-50.0 mm. (See NOTE 2.)
time is a +0.5 mm change, up to
+50.0 mm. (See NOTE 2.)
EO18-33006