Menu Configuration; Submenu Control Interface - AVT MAGIC AE1 DAB+ Hardware & Software Manual

Dab+ audio encoder
Hide thumbs Also See for MAGIC AE1 DAB+:
Table of Contents

Advertisement

W i n d o w s
P C
S o f t w a r e
P A GE 3 4
5.5

Menu Configuration

FIG. 10
5.5.1

Submenu Control Interface

The system can be connected via the serial RS232 interface with a 1:1 connect-
ing cable or via the LAN interface to a PC. The configuration of the Control In-
terface of the PC can be carried out under Configuration

face
Configuration.
Using the RS232 interface
If you want to use the RS232 interface select via the drop-down list Interface

RS232.
FIG. 11
As Port you select the interface of your PC which is connected to the MAGIC
AE1 DAB+.
Under Mode you can set the desired operating mode:
– 9600 Baud
– 19200 Baud
– 38400 Baud
– 57600 Baud
– 115200 Baud
All further parameters like Data Bits, Parity and Stop Bits cannot be config-
ured.