10-MAINTENANCE AND CLEANING
END-OF-SEASON SHUTDOWN
At the end of season, before shutting down the boiler, we recommend completely removing pellets from the hopper with the use of a
vacuum cleaner with an extension.
The service fuse may have to be replaced if the control panel display does not go on when the product is re-started upon pressing the main
switch on the rear of the boiler.
On the rear of the boiler there is a fuse compartment which is located underneath the supply socket. Use a screwdriver to open the fuse
compartment and if necessary replace them (3.15 A delayed).
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
It is recommended to perform this routine maintenance annually (with a scheduled service contract), which focuses on a visual and
functional verification of the internal components. The following is a summary of the necessary checks and/or maintenance for the
product to work correctly.
Gear motor
Smoke expulsion fan
Smoke probe
Start-up spark plug
Automatic resettable pellet/water thermostat
Room/water probe
Motherboard
Panel - motherboard protection fuses
Cabling
54