RED COMPACT 35 Installation And User Manual page 54

Pellet boiler
Hide thumbs Also See for COMPACT 35:
Table of Contents

Advertisement

10-MAINTENANCE AND CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE EXCHANGER AND PIPE UNIT
CLEANING THE UPPER COMPARTMENT
When the boiler is cool, lift the front cover "I"; unscrew the screws on the rod "D" to clean the pipe unit and take out the two beams "A".
Now take off the cover "B". Then, take off screws "V" (two on the right and two on the left) that hold the turbulators to the boiler.
At this point, remove the four turbulators "C" and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators,
removing all of the accumulated ash.
Check the cover gasket and replace it if necessary.
D
A
B
V
V
C
I
G
E
H
F
52

Advertisement

Table of Contents
loading

Table of Contents