8 - MENU ITEMS AND OPERATION
SYSTEM CONFIGURATIONS
Upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the "SETTINGS" menu.
The possible configurations are 5, as described below:
Configuration
Description
1
Room temperature management via the boiler probe or by enabling the external room thermostat.
2
2.1 Room temperature management via the boiler probe or by enabling the external room thermostat;
instantaneous hot domestic water production with plate heat exchanger (FACTORY CONFIGURATION).
2.2 Room temperature management via the boiler probe or by enabling the external room thermostat;
instantaneous hot domestic water production for boiler or storage tank with thermostat (optional).
3
Room temperature management via boiler probe or enabling the external room thermostat; boiler hot domestic
water production with ntc probe (10 kΩ ß3435).
4
External Puffer management controlled by thermostat.
5
External Puffer management controlled by ntc probe (10 kΩ ß3435).
CONFIGURATION 1