3-DRAWINGS AND TECHNICAL SPECIFICATIONS
TECHNICAL CHARACTERISTICS
Product class (EN 303-5:2012)
Nominal thermal power to firebox
(Max) nominal output power:
Minimum output power
Efficiency at Max
Efficiency at Min
Temperature of exhaust smoke at Max
Temperature of exhaust smoke at Min
Maximum temperature that can be set
Maximum operating temperature
Particulate/OGC / Nox (10%O
2
CO at 10% O
at Min and at Max
2
CO
at Min and at Max
2
Recommended draught at Max power
Recommended draught at Min power
Mass of smoke
Hopper capacity
Type of pellet fuel
Pellet hourly consumption
Autonomy
Heatable volume m3
Water content
Maximum operating pressure
Combustion air inlet
Smoke outlet
Air inlet
Nominal electrical power (EN 60335-1).
Supply voltage and frequency
Net weight
Weight with packaging
* Data that may vary depending on the type of pellets used.
**Heatable volume based on the requested power per m3 (respectively 40-35-30 Kcal/h per m3)
18
)
COMPACT 35 HYDRO
5
34,5 kW (29670 kcal/h)
32,0 kW (27520 kcal/h)
8,1 kW (6966 kcal/h)
92,8%
90,0%
140°C
60,5°C
80°C
95°C
23 mg/Nm
- 2 mg/Nm
- 196 mg/Nm
3
3
0,014 - 0,005%
5,6 - 10,3%
0.10 mbar - 10 Pa
0.05 mbar - 5 Pa
21.5 g/sec
146 litres
Pellet diameter 6-8 mm and size 5/30 mm
Min ~ 1.3 kg/h* - Max ~ 6.7 kg/h*
At min ~ 80 h* - At max ~ 16 h*
688/40 - 786/35 - 917/30**
30 litres
3 bar - 300 kPa
External diameter 80 mm
External diameter 100 mm
100 cm
2
190 W (Max 440 W)
230 Volt / 50 Hz
300 kg
320 kg
3