SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY
OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW
ALL SAFETY INSTRUCTIONS IN ThE MANUAL AND ON
ThE PUMP .
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or
in the manual, look for one of the following
signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that WILL cause serious
DANGER
personal injury, death or major property
damage.
Warns of hazards that CAN cause serious
WARNING
personal injury, death or major property
damage.
Warns of hazards that CAN cause personal
CAUTION
injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND
MUST BE FOLLOWED.
THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND
WARNINGS PRIOR TO PERFORMING ANY WORK
ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
NOTICE: INSPECT UNIT FOR DAMAGE AND
REPORT ALL DAMAGE TO CARRIER
IMMEDIATELY.
UNIT NOT DESIGNED FOR USE
WARNING
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES.
Hazardous fluids
can cause fire,
burns or death.
DESCRIPTION and SPECIFICATIONS
The series 3656/3756 are single stage, end suction, centrifugal
pumps for general liquid transfer, booster applications, irriga-
tion and general service pumping. Pumps are available in three
different materials of construction: all iron, bronze-fitted and
all bronze ("S" group only).
Pump impellers are fully enclosed, key driven and held in
position by an impeller bolt and washer. Casings are full volute
in design with replaceable wear rings.
Dependant on the pump size, the suction and discharge
connections will be threaded or flanged. Shafts are protected
with stainless steel shaft sleeves.
Close-coupled units have NEMA standard JM or JP motors
with C-face mounting and key driven shaft extension. SAE
drive units bolt directly to the engine flywheel housing for SAE
sizes 1, 2, 3, 4 or 5. Optional elastomer element couplings
are available for 6½, 7½, 8, 10, 11½ and 14 inch flywheels.
Frame mounted units can be coupled to motors through a
spacer coupling, or belt driven.
2
Engineering Data
Maximum Liquid Temperature:
212º F (100º C) – standard seal or packing
250º F (120º C) – Optional high temp. seal
Maximum Working Pressure (Fluid temperature dependant):
– NPT connections, 200 PSI (1379 kPa)
– 125# ANSI flanged connections, 200 PSI (1379 kPa)
Maximum Suction Pressure: 100 PSI (689.5 kPa)
Starts per Hour: 20, evenly distributed
Group
Size
1½ x 2-6 (H)
1 x 2-7
2½ x 3-7
S
3 x 4-7
1 x 2-8
1½ x 2-8
2 x 2-5
2½ x 2½-5
LH
3 x 3-5
4 x 4-5
5 x 5-6
2½ x 3-8
3 x 4-8
4 x 5-8
1½ x 2-10
2½ x 3-10
M
3 x 4-10
4 x 6-10
2½ x 3-13
3 x 4-13
4 x 6-13
6 x 8-13
L
8 x 10-13
4 x 6-16
Installation
loCATion
• Locate the pump as near liquid source as practical; below
level of liquid for automatic repriming capability.
• Allow adequate space for servicing and ventilation. Protect
the unit from weather and water damage due to rain,
flooding or freezing temperatures.
• Protect the pump and piping from freezing temperatures.
• Allow adequate space around the unit for service and
ventilation.
CloSE-CoUPlED UniTS
• Units may be installed horizontally, inclined or vertically with
the motor above the pump.
• The motor feet MUST be bolted to a substantial surface
(horizontal or vertical) that is capable of complete and rigid
support for the pump and motor. For L-Group pumps, the
motor adapter feet must also be bolted to the supportive
surface.
• For vertical operation, the motor should be fitted with a drip
cover or otherwise protected against liquid entering the mo-
tor (rain, spray, condensation, etc.)
NOTICE: DO NOT INSTALL WITH MOTOR
BELOW PUMP . ANY LEAKAGE OR
CONDENSATION WILL AFFECT
THE MOTOR.
Suction
Discharge
2" NPT
1½" NPT
2" NPT
1" NPT
3" NPT
2½" NPT
4" Flange
3" Flange
2" NPT
1" NPT
2" NPT
1½" NPT
2" NPT
2" NPT
2½" NPT
2½" NPT
3" NPT
3" NPT
4" Flange
4" Flange
5" Flange
5" Flange
3" NPT
2½" NPT
4" Flange
3" Flange
5" Flange
4" Flange
2" NPT
1½" NPT
3" Flange
2½" Flange
4" Flange
3" Flange
6" Flange
4" Flange
3" Flange
" Flange
4" Flange
3" Flange
6" Flange
4" Flange
8" Flange
6" Flange
10" Flange
8" Flange
6" Flange
4" Flange

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

3756

Table of Contents