Replacement routines
Ê Thread the intrusion switch cable through the recess.
Figure 17: Removing the intrusion switch 2
Ê Remove the two screws (see the arrows) and take out the intrusion switch
inward.
Ê Remove the intrusion switch cable from the connector on the system board
(see also the Technical Manual of the system board).
Ê Plug the new intrusion switch cable to the connector on the system board.
Ê Route the intrusion switch cable as before.
Ê Position the intrusion switch with the three wires on the front cover and
fasten it with two screws.
Ê Push the intrusion switch with the two wires in its holder until it clicks in.
Ê Reinstall the front cover or the rack front cover, close the server and connect
all power plugs (for a detailed description see the Options Guide).