■ STARTING SEQUENCE
● Starting mode (List)
Mode
Normal (Refresh)
Started with DIP switches [7][8] set
mode
to OFF([5][6] OFF).
Normal (Resume)
Started with DIP switch [7] set to
mode
ON([5][6] OFF).
Started with DIP switch [5] set to
AD8HR mode
ON and [6] OFF.
Started with DIP switch [7] set to
Firm Update mode
OFF and [8] ON.
Started with DIP switch [7] set to
Diag mode
ON and [8] ON.
DEVICE ID set to [0].
Started with DIP switch[7] set to
Through mode for
ON and [8] ON.
service inspection
DEVICE ID set to [7] or [8].
● Starting mode (Flow chart)
Normal mode
DIP switch
[7] OFF [8] OFF(Refresh)
[7] ON [8] OFF(Resume)
[5] ON [6] OFF(AD8HR)
Power ON
Starting Boot Program
Checking existence of inspection PCB
(Exists)
When starting mode is Update
When starting mode is Diag
Starting Main Program
Reading parameters from Flash ROM
Judging checksum of above read parameters
(OK)
(NG)
Initializing all parameters
When starting mode is Refresh
Initializing parameters other than FS, WC Master, Dante settings
92
Mode transition method
Description of operation
Parameters other than Fs, WC Master are initialized.
All parameters have been backed up.
This mode is selected to control Rio using the mixer for AD8HR other than CL.
Parameters are the same as those in Resume mode.
All +48V LEDs fl ash.
SWX02 fi rmware is updated via the network.
MAC address and serial number are written.
Starting is judged on the Boot side.
All SIGNAL LEDs fl ash.
Rio is checked via the network.
Starting is judged on the Boot side.
Redundant mode should be selected by setting DIP switch [4] to ON.
When DEVICE ID is [7], the input at INPUT 1-8, 17-24 is output at OUTPUT 1-16.
When DEVICE ID is [8], the input at INPUT 9-16, 25-32 is output at OUTPUT 1-16.
Starting is judged on the Boot side.
Firmware Update mode
DIP switch
[7] OFF [8] ON
Update indicated on panel LED
Update executed.
Power turned off.
Diag mode
DIP switch
[7] ON [8] ON
When PCB exists, the starting
mode becomes Diag.
Diag indicated on panel LED.
Diag executed.
Power turned off.