Jumper Settings of PEB-973L

To set jumper positions, place the jumper shunt over the pins designated in the table (SHORT) or remove
(NC) it from the jumper pins and store for future use. Default settings are indicated with a star sign ().
JP1
CMOS RAM Charge/Discharge setup
JP1
1-2
NORMAL 
2-3
Clear CMOS
JP2
Secondary RTC Function
JP2
1-2
NORMAL 
2-3
Clear CMOS
JP4
LVDS Panel VDD Input Voltage Selection
JP4
1-2
VDD=3V 
5-6
VDD=5V
JP5
LVDS Panel Backlight Enable Voltage Selection
JP5
1-3、2-4
5V, Active High 
1-3、4-6
3V, Active High
5V, Active Low
3-5、2-4
3-5、4-6
3V, Active Low
JP6
LVDS Panel Backlight Control Mode
JP6
Open
Backlight control use PWM mode
Short
Backlight control use voltage mode 
JP7
mSATA / PCIe Function Selector
JP7
1-2
Enabled mSATA function 
2-3
Enabled PCIE and MiniPCIE function