Parts supplied
Tap options
Command-Centre
QUICK START GUIDE
STEP 1-
Prepare and fit the Taps
Note: This quick start guide must be read in conjunction with
HydroTap Tap
All-In-One Tap
the main installation and user instructions
(If required)
•
Before proceeding, read the installation and user instructions
For AIO mains and vented Taps
•
Check all the components are present and correct.
•
Cut a 50mm hole in the bench / sink top.
Check that you have all the necessary tools
•
Ensure the underbench can support the product weight when full of water,
(Check the specifications in the main book and allow an extra 5-8kg when full. )
Black plastic
SINK TOP
spacer
Before installing ensure the following have been provided at
50mm
the installation site:
ALL THREAD
ROD
Stainless
•
Sufficient space in the cupboard to install all of the undersink units in accordance
washer
with these Installation Instructions. Refer to technical specification for dimensions. If
NOTE: make sure the tap location will allow the nozzle to drain into the sink.
required, make allowance for a booster heater. (Refer to the main book, for detailed
SPIDER
Fit the
CLAMP
installation instructions).
STAINLESS
•
A potable water supply connection with isolating valve inside the cupboard within
BLACK
STAINLESS STEEL
reach of the flexible braided hose and positioned so that the connection point and the
PLASTIC
STEEL
WASHER,
6mm
SPACER
WASHER
SPIDER CLAMP,
NUT
stop cock will not be obstructed when all the undersink units are installed.
AND 6mm NUT.
•
For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be
required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be
SPIDER
CLAMP
required. (One GPO is for the Zip HydroTap and the other for the Booster heater).
NOTE: feed each of the three tubes and
NOTE: Check the cable lengths and outlet positions before proceeding.
electrical cable evenly in between the legs of
O-RING
•
A potable cold water supply with a minimum working pressure of 172kPa and a
NUT
the SPIDER CLAMP when installing.
maximum working pressure of 700kPa connected via an isolation valve.
35mm dia hole
•
For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.
Hole positioning:
BASE
Position the tap such that it dispenses into
BLOCK
ALL
•
The undersink appliances must be mounted in upright positions as shown in the
the sink bowl with ample clearance for a cup or tea pot. Alternatively,
SPIDER
THREAD
O-RING
diagrams.
the tap could be mounted away from the sink using a Zip Font, avail-
ROD
SINK TOP
Sink
able as an accessory.
BASE
IMPORTANT!
BLOCK
Do not proceed with the installation if these
Apply a light smearing of silicon sealant
NUT
requirements are not met.
USB
on the underside of the upper spacer to
CABLE
ensure a watertight fi t.
Parts Supplied
Description
Parts Supplied
Description
Mixer Tap
Fit the O-ring to the underside of the AIO tap
4-in-1
(If required)
then pass all hoses through the 50mm hole.
Duct kit
1 off
1x Air Duct
Hydrotap Tap
and hoses
1 x Mounting
plate
Tap
Vent kit
O ring Base
1 off
UPPER
Undersink Unit
1 x Kickboard
RUBBER
UPPER RUB-
louvre
WASHER
BER WASHER
Chiller
with air and water-
1 x Door vent
filter
Clear tube to Vent
connection
louvre
BLUE
1 x front vent grill
LOWER RUBBER
NOTE: feed each of
WASHER
LOWER RUB-
the tubes and elec-
Boiler
BER WASHER
trical cable evenly in
connection
1 off
WASHER
WASHER
between the legs of
RED
1 x Restrictaflow
HydroTap
the BASE BLOCK
valve and Tee
Booster heater
NUT
BRAIDED
SPIDER.
piece for Mixer
and hoses
NUT
Taps
(Supplied with
HOSE x 3
240/175 models)
White Hose
White ring
Blue ring on
For HydroTap and Mixer taps
Ext. Mains
on LHS to
RHS mains IN to
Mains in
Mixer IN
cut a 35mm hole in the bench / sink top.
1 off Mains water
Blue band
BENCH TOP
Mixer IN
From Mixer OUT to Tap - Vented version only
connection hose
Ø35mm
Red band
Mixer Out
801600 - Zip Quick Start Guide - October 2013 - V1.06
Page 8 of 20
Major components and accessories
Description
1 x HydroTap
Classic
Elite or
Arc / Cube
#
(inc. Tube kit)
#
and components
TM
Vent kit
2 x outlet vent
1 x inlet vent
1 x
Command-Centre
with air and water
filters
1 x Mains water
connection hose
1 x User guide and
ZIP HydroTap
®
User Guide
1 x Quick start
Tap Operation...................(Pages 2-5)
•
LCD Screen & Menu .......(Pages 6-18)
•
Maintenance.................... (Pages 18-20)
•
Date of Installation.........
•
BC160/125G4
BC240/175G4
BCH160/125G4
BCH240/175G4
AV160/125G4
guide
AN160/125G4
AV240/175G4
AN240/175G4
1 x Installation
Affix Model Number Label
Here
801599
instruction
801599 - HydroTap User Guide - Nov 2013 UK - V1.05
Page 1 of 20
1 x
CO
gas cylinder
2
assembly
804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02
Accessories
G4
®
TM
For Accessories contact Zip:
Tel 0345 6 005 005
Website: www.zipwater.com/uk
Email: sales@zipindustries.co.uk
Description
Font kit
Classic & Elite
or
Arc / Cube
Replacement
internal 0.2 micron
filter
Disabled lever kit
(Classic HydroTap
)
®
1 X
CO
gas cylinder
2
Recommended
water block
Need help?
Do you have a question about the Command-Centre and is the answer not in the manual?