Operation And Speed Command Source (Pr. 338, Pr. 339, Pr. 550) - Mitsubishi Electric FR-A7NC Instruction Manual

Plug-in option
Hide thumbs Also See for FR-A7NC:
Table of Contents

Advertisement

4.3

Operation and speed command source (Pr. 338, Pr. 339, Pr. 550)

(1) Select command source for the Network operation mode (Pr. 550)
A control location for the Network operation mode can be selected from either the inverter RS-485
terminals or a communication option.
When using a communication option, set "0 or 9999 (initial value)" in Pr. 550.
Parameter
Number
NET mode operation
550
command source selection
Refer to the Inverter Manual for details.
Name
Initial Value
9999
INVERTER SETTING
Setting
Description
Range
Command source is at a
communication option
0
(Command source is not at inverter
RS-485 terminals)
Command source is at inverter RS-
485 terminals
1
(Command source is not at a
communication option)
Automatic recognition of the
communication option
Normally, command source is at RS-
9999
485 terminals. When a
communication option is mounted,
the command source is at a
communication option.
4
25