I/O SIGNAL LIST
(2) Remote register
Description
Address
Upper 8 Bits
RWwn
Monitor code 2
Set frequency (0.01Hz increments)
RWwn+1
/ torque command
RWwn+2
H00 (arbitrary)
RWwn+3
("n" indicates a value determined according to the station number setting.)
*1
The above 8 bit is always H00 even if a value other than H00 is set.
*2
For the FR-A700 series, setting "3" or "5" in Pr.804 during torque control under Real sensorless vector control or
vector control sets torque command in RWwn + 1.
48
Refer
Lower 8 Bits
Page
Monitor code 1
*2
Instruction code
*1
Write data
to
Address
63
RWrn
63
RWrn+1
64
RWrn+2
64
RWrn+3
Description
First monitor value
Second monitor value
Reply code
Read data
Refer
to
Page
67
67
67
67