(1) Device list
W1
W2
W3
W4
W5
W6
W7
W8
W9
WA
WB
WC
WD
WE
W80
W81
D20
D21
D22
D23
D31
D32
X20
X21
X22
X23
X24
X25
Y30 to Y3F
X1000
X1007
X100F
Y1005
Y1006
Y1009
Y100F
Device
Device to which CH1 Scaling value is written by auto refresh
Device to which CH2 Scaling value is written by auto refresh
Device to which CH3 Scaling value is written by auto refresh
Device to which CH1 A/D conversion completed flag is written by auto refresh
Device to which CH2 A/D conversion completed flag is written by auto refresh
Device to which CH3 A/D conversion completed flag is written by auto refresh
Device to which CH3 Input signal error detection flag is written by auto refresh
Device to which CH1 Error code is written by auto refresh
Device to which CH2 Error code is written by auto refresh
Device to which CH3 Error code is written by auto refresh
Device to which CH4 Error code is written by auto refresh
Device to which CH5 Error code is written by auto refresh
Device to which CH6 Error code is written by auto refresh
Device to which a common error code is written by auto refresh
Device to which CH5 Digital input value is written by auto refresh
Device to which CH6 Digital input value is written by auto refresh
Representation error
CH1 Scaling read value
CH2 Scaling read value
CH3 Scaling read value
CH5 Initial digital input value
CH6 Initial digital input value
Device turned on by user to start reading
a scaling value
Device turned on by user to set initial
digital input value
Device turned on by user to write digital
input value
Device turned on by user to enable
analog outputs of all channels
Device turned on by user to reset input
signal error detection
Device turned on by user to reset an error
Error code display (4 digits in BCD)
Module ready
Input signal error detection signal
Error flag
CH5 Output enable/disable flag
CH6 Output enable/disable flag
Operating condition setting request
Error clear request

9.3.2 Program example using the utility package

Table 9.11 Device list
Function
Q64AD2DA (X/Y1000 to X/Y100F)
9.3 Programming for Remote I/O Network
QX10 (X20 to X2F)
QY10 (Y30 to Y3F)
9
- 22
9
10
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw2d5c-qadu-eSw2d5c-qdau-e

Table of Contents