D9412G/D7412G
Arming Devices
To
Panel
Switching the green and yellow wires affects other command centers: Incorrectly connecting the green wire
from the command center to Terminal 31 and the yellow wire to Terminal 30, causes other command centers
connected to the panel to go blank and/or sound random beep tones.
Devices can be connected to the data bus, Terminals 30 and 31, by parallel wire runs from the panel to each
device, wire from device to device, or a combination of the two as long as a maximum of 15,000 ft. (4,572 m) of 22
AWG wire for all devices connected to the SDI Bus combined is used.
It is recommended, however, that command centers be limited to 2,000 ft. (610 m) per run; D9210B Modules be
limited to 1,500 ft. (457 m) per run (2,500 ft. [762 m] if using an external power supply), and the D9131A be limited
to 1,000 ft. (305 m) per run.
Extra power needed for more command centers: The D1255 Command Center draws 104 mA when it is idle. It
draws 206 mA with the keys lit and the sounder activated. Review section 5.0 Power Outputs to determine the total
power output requirements for the system.
One or more D8132 Battery Charger/Power Supply Modules may need to be added for the number of command
centers that will be used. Figure 19 shows the D8132 powering command centers in a stand-alone configuration.
For UL certificated accounts use a UL listed power supply. The D8132 is not UL listed as a stand-alone power
supply.
Control/Communicator and D8132 (or other power supply) must share COMMON: Note that Figure 19
shows the common from the D8132 Module connected to both the command centers' common and the
common on the control/communicator. Any stand-alone power supply powering any device connected to the
panel must also be connected to a common terminal on the panel.
If you are using the Ground Fault Detect capability on the D9412G or D7412G Control/Communicators and
an external power supply, make sure that the external power supply selected isolates its Earth Ground
connection from the negative side of the Aux Power output. External power supplies that do not isolate Earth
Ground will cause ground fault conditions on the Control/Communicator.
10.3

D268/D269 Independent Zone Control, D279A Independent Zone Control

Any on-board or OctoPOPIT point can be programmed so that the D268/D269 or D279A Independent Zone
Control operates as independent point control (arms and disarms the point).
See the Point Assignments in the D9412G/D7412G Program Entry Guide for programming information. See the
D268/D269 Operation and Installation Instructions (P/N 74-05439-000) or the D279A Operation and Installation
Instructions (P/N 46456) for wiring and operation instructions.
43488D

Figure 19: Power at Command Centers

D9412G/D7412G Operation & Installation Guide
Page 54
+12 VDC
DATA
DATA
COMMON