An example of the facilities, equipment, operations, or procedures that line is shown in the margin to the left of this could affect the operation of the D2112. If this paragraph. happens, the telephone company will provide...
D2112/D2112E Control/Communicator .... 4 Terminals 15 to 22 (14 to 22 on D2112E) ..10 Ordered Separately .......... 4 Points 7 and 8 on the D2112 Only Enclosure Options ..........4 Terminals 23 to 25 .......... 10 Listings and Approvals ........4 Program the Panel ..........
Introduction Enclosure Options The D2112 and D2112E are shipped in the D2103 D2112/D2112E Control/Communicator enclosure. If you want to mount the D2112 or The Radionics D2112 and D2112E Control/ D2112E in one of the optional enclosures listed Communicators are shipped pre-assembled from the below, order the D2112M or D2112EM, and the factory.
• High voltage electrical equipment (Electro-Magnetic Interference) problems. • PBX telephone system On the D2112, wire resistance on the Point 1 sensor • Public service (police, fire departments, etc.) loop must be less than 50Ω. Measure the wire using radio communications resistance before installing smoke detectors.
Lock the pin down now. See burglary systems: In order to meet standby battery Figure 2. requirements, use the Radionics D126, 12 V 7.0Ah With the Standby Switch locked down, the panel battery for fire and combined fire/burglary systems.
Radionics D126, 12 V 7.0Ah battery for fire and combined fire/burglary systems. When using the D2112's Point 1 as a fire point, the number of devices you can connect to it's sensor Power restricted for fire and combined fire/ loop is limited.
Outputs on page 14 to determine the total power the keypad. For more information about this and output requirements for your system. Instructions for other keypad diagnostic features, see the D2112 using stand alone power supplies are included. Keypad Diagnostics manual (74-07113-000).
The D2112E's Aux Power and Bell outputs are protected by 2 Amp fast blow fuses. The fuses are 5 mm x 20 mm, 2 Amp Fast Blow (Radionics Part # 57-03570-008). To test the fuses, use a Volt/Ohm meter to follow these steps: 1.
Connect up to five Radionics D262 two-wire smoke function. See RELAYS in the D2112/D2112E detectors to point 1 on the D2112. Refer to the Program Entry Guide for programming instructions. Technogram, Smoke Detectors Compatible with the...
Connect the battery and then plug in the programmed Point 1 for Fire with Verification transformer. (Digit 1 = 2). See POINT CODES in the D2112/ Leave the Standby Switch locked down for now. D2112E Program Entry Guide for more information.
You can program the panel to use DTMF or pulse both the auxiliary and alarm power outputs. dialing. See Phone Parameters in the D2112/ D2112 bell circuit protection: A short on alarm D2112E Program Entry Guide . power output while the bell is ringing disables the...
Point 1 is a powered sensor loop. Review the You can connect a momentary contact arming Radionics Technogram: Smoke Detectors station (keyswitch) to turn the D2112 on and off. The Compatible with the D2112 (73-07115-000) for a list keyswitch is connected to a point sensor loop (points of compatible detectors.
Page 16
Keyswitch Operation Easikey Shorting and restoring the point sensor loop toggles You can use a Radionics Easikey access system to the system On and Off. All faulted points are turn the system Off. Program the Keyswitch Keyswitch prompt bypassed. See POINT CODES Group in the D2112/ to Easikey.
System Chart. See the for Standby Battery Calculations. installation and operation instructions for each D2112 only: Two-wire detectors must be electrically component for detailed instructions. compatible, and must be UL listed for use with the D2112.
1 If Total A exceeds 860 mA, a stand-alone power supply is required to provide additional current. 2 If Total C exceeds 860 mA for fire systems, a stand-alone power supply is required to provide additional current. D2112/D2112E Installation Manual Page 18 74-07111-000-D 196...
System Chart D2112 and D2112E not listed for these applications NFPA Standard 71, 72 71, 72 Minimum Hours 24 + 24 + of Standby 4 mins 4 mins Battery alarm alarm No = Not acceptable for this application Included with panel.
9 (140mA for Fire Compatible Accessories (D2112 and D2112E) and combined Fire/Burglary systems) . See the Radionics Product Catalog for complete list. Alarm Power Output • D126 12V, 7 Ah Rechargeable Battery • 1.5 A maximum at 10.2 VDC to 13.9 VDC output.