Off-board Points
The sixth column shows the
Debounce Count for the point. See
Debounce Count in the D9412G/
D7412G Program Entry Guide .
The seventh column shows the
BFSK report code. It is the point
number reported for this point when
the panel is using the BFSK format.
The eighth column contains the text
displayed at command centers for
the point. The text is transmitted to
the receiver when the panel is using
2
the Modem IIIa
format.
POPIT Labels
Off-board points for the D9412G are
numbered 9 to 127 and 129 to 247
(D7412G uses Points 9-75 only).
The D9412G reserves Points 128
and 248 for internal use. POPITs
must be connected for Points 129 to
247 to expansion loops connected to
POPEX #2.
Two sheets of peel-off POPIT labels are supplied with the D8125 POPEX Module. Use the sheet marked Bank1
for Points 9 to 127. Use the sheet marked Bank2 for Points 129 to 247.
Each label has two parts. Place the smaller part, with just the point number on it, on the chip. Place the larger part
with the switch settings on the base of the POPIT. Set the switches and cover the POPIT.
Do not program two POPITs for the same point number. After programming all the points, perform a service walk
test. The D9412G/D7412G Installation and Troubleshooting Quick Reference Guide contains instructions for
performing a service walk test. If a point does not test, check the programming for a duplicated address.
Walk test does not show extra points: Only the Service Walk Test shows extra points. If the point assignment
switches on a POPIT or OctoPOPIT are set incorrectly, it may create both missing and extra points. If the same
point number is assigned to two or more POPITs or OctoPOPITs, none of the points with that number will test
correctly.
8.4

D8128D OctoPOPIT Module

D8128, D8128A or D8128B modules are not compatible with the D9412G or D7412G. Only use the D8128D
OctoPOPIT module. Using D8128, D8128A or D8128B modules may cause intermittent missing and
restoral reports.
8.4.1

Description

The D8128D OctoPOPIT Module combines the functions of the D8125 POPEX module and the D8127/D9127
POPIT modules to provide eight off-board points in a single module. You can wire both D8128D OctoPOPIT and
D8125 POPEX modules in parallel to the ZONEX Bus terminals on the same panel.
Review section 5.0 Power Outputs to be sure to provide enough power for the OctoPOPITs and other powered
devices that will be connected to the system.
8.4.2

Listing

The D8128D OctoPOPIT Module is UL listed for Local or Police Connected Burglary Alarm, Central Station Burglary
Alarm, and Household Burglary Alarm applications. The D8128D is also suitable for fire supervisory applications,
such as indicating circuit supervision (using the D192C Bell Circuit Supervision Module), sprinkler supervision,
and valve tamper protection.
Do not connect fire alarm initiating devices directly to the D8128D.
You must use the D125B Dual Class B Powered Loop Interface Module or D129 Dual Class A Initiation Circuit
Module for fire initiation applications. Connect the initiating devices, smoke detectors for example, to the D125B
powered loops or D129 Class A loops.
43488D
D9412G/D7412G
RADXPNTS Handler
Point Assignments (001 through 040)
POPIT Switch
Trans-
Setting
lation
100
200
300
400
500
600
700
800
0 1 2 3 4 5 6
101
0 1 2 3 4 5 _
102
0 1 2 3 4 _ 6
103
0 1 2 3 4 _ _
104
0 1 2 3 _ 5 6
105
0 1 2 3 _ 5 _
106
0 1 2 3 _ _ 6
107
0 1 2 3 _ _ _
108
0 1 2 _ 4 5 6
109
0 1 2 _ 4 5 _
110
0 1 2 _ 4 _ 6
111
0 1 2 _ 4 _ _
112
0 1 2 _ _ 5 6
113
D9412G/D7412G Operation & Installation Guide
Page 44
Point
Point
Area
Debounce
#
Index
Assign
001
__ __
(1)
____
(2)
_____
002
__ __
(1)
____
(2)
_____
003
__ __
(1)
____
(2)
_____
004
__ __
(1)
____
(2)
_____
005
__ __
(1)
____
(2)
_____
006
__ __
(1)
____
(2)
_____
007
__ __
(1)
____
(2)
_____
008
__ __
(1)
____
(2)
_____
009
__ __
(1)
____
(2)
_____
010
__ __
(1)
____
(2)
_____
011
__ __
(1)
____
(2)
_____
012
__ __
(1)
____
(2)
_____
013
__ __
(1)
____
(2)
_____
014
__ __
(1)
____
(2)
_____
015
__ __
(1)
____
(2)
_____
016
__ __
(1)
____
(2)
_____
017
__ __
(1)
____
(2)
_____
018
__ __
(1)
____
(2)
_____
019
__ __
(1)
____
(2)
_____
020
__ __
(1)
____
(2)
_____
021
__ __
(1)
____
(2)
_____

Figure 15: Program Record Sheet

Default values are shown in ( ) or in bold
BFSK/
Custom Point Text
Relay
P1 FIRE
(1)
____
___________________
(2)
____ P2 PANIC
___________________
(3)
____ P3 DELAY
___________________
(4)
____ P4 FOLLOW ___________________
(5)
____ P5 INSTANT ___________________
(6)
____ P6 INSTANT ___________________
(7)
____ P7 INSTANT ___________________
(8)
____ P8 INSTANT ___________________
(1)
____ P9
___________________
(1)
____ P10
___________________
(1)
____ P11
___________________
(1)
____ P12
___________________
(1)
____ P13
___________________
(1)
____ P14
___________________
(1)
____ P15
___________________
(1)
____ P16
___________________
(1)
____ P17
___________________
(1)
____ P18
___________________
(1)
____ P19
___________________
(1)
____ P20
___________________
(1)
____ P21
___________________
© 2002 Radionics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents