Available languages

Available languages

INSTALLATION MANUAL
SUBLIM
Illuminated Weatherproof Keypad with remote electronics
5] SUBLIM 2 RELAYS CONNECTION DIAGRAM
Fail secure strike
Varistor
Fail safe strike
(Contact on standby)
H (Open)
SUBLIM in coded keypad operation
H (Closed)
SUBLIM in Push Button operation
Power supply
12 to 24V AC
or 12 to 48V DC
Terminal
block
1
+ Power supply 12V to 24V ac or 12V to 48V dc
2
- Power supply 12V to 24V ac or 12V to 48V dc
3
Exit push button, relay 2
4
Button common
Exit push button, relay 1
5
6
Extension contact L
7
Common contacts
Clock switch
8
NC
Standby switch of relay 1 (Normally Connected)
C1
Common contact of relay 1
NO
Working switch of relay 1 (Normally Open)
NC
Standby switch of relay 2
C2
Common contact of relay 2
NO
Working switch of relay 2
9
keypad green light (white wire)
keypad blue light (blue wire)
10
11
Buzzer (Black wire)
12
Sensor 2 (Black wire)
13
Sensor 1 (Gray wire)
14
Common Sensor (Shield) put together
15
Common LED and buzzer (Red wire)
cdvi.com
14
cdvigroup.com
Detail
SW2
I1
SW1 - Reset in the ON position:
1.
With the power on,
reinitializes the master
code 1 2 3 4 5.
With the power off,
reinitializes the memory :
- master code,
- deletion of user codes,
- default factory settings.
2. Change of code by the user
in the ON position.
3. Not used.
4. Not used.
SW2 - Training mode
Must be in the ON position with the
power off to switch to training mode.
SW3 - Reset
Do not use. Must be set to OFF.
I1 - Must be set to ON.
SW1
SW3
Relay
Relay
1
2
Power supply
power side
of Exit command
12/24/V AC or 12/48/V DC
Push button control
Connecting push button P1
is used to control relay 1.
Connecting push button P2
is used to control relay 2.
The mode and timeout
are programmable.
Clock contact H
lets you use all the keys
as external buttons.
If the clock contact is open,
the keys are used as normal
digits. If the clock contact
is closed, all the keys are
used for free access.