Fluke 6060B Instruction Manual page 19

Synthesized rf signal generator
Hide thumbs Also See for 6060B:
Table of Contents

Advertisement

INTRODUCTION
AND
SPECIFICATIONS
Tabl«
1-1.
Signal
Gonerator
Specifications (cent)
AMPLITUDE SWITCHING SPEED
<100
ms to be
within
0.1 dB.
AMPLITUDE RANGE
ProgrammabLe to +19 dBm and
-U7.4
dBm, usable to +15 dBm. Pixed-range,
selected by special function, allows
for
more than
12 dB
of
vernier without
switching the attenuator.
NOISE
Cat
20-kHz offset)
<-113 dBc/Hz (except <-107 dBc/Hz
below 245 MHz and above 512 MHz).
RESIDUAL
FM
Crms in 0-3 to
3
kHz)
Approximately
a
linear function
of
output frequency
between the following
typical band-edge values:
15 Hz at 0-1 MHz to 17
Hz at
244.99999
MHz.
6 Hz at
245 MHz to
8 Hi at
511-99999
MHz.
12
Hz at
512
MHz to 17
Hz
at
1050
MHz.
EXTERNAL MODULATION
Annunciators indicate when
a
IV peak
signal
is
applied, ±2%, over
a
0.02-
kHz to
100-kHz band.
IEEE
All
controls except the power switch
and the
internal/external reference
switch are remotely programmable via
IEEE-488 Interface
(Std
488-1978).
ALL
status including the option
complement are available remotely. The
Store/Recall memory data may
be
transferred via
an
external controller-
In
talk-only, the appropriate commands
are generated when the front
panel
step-up and step-down entries are made
to control
another 6060B,
a
6060A,
a
6070A,
or a 6071
A.
(The
6070A
and
6071A
only have FREQUENCY STEP.)
frequency drift
<1
ppm/hr after 1-hour warmup
at
constant ambient temperature using
internal free-air crystal.
1-9/MO