Fluke 6060B Instruction Manual page 125

Synthesized rf signal generator
Hide thumbs Also See for 6060B:
Table of Contents

Advertisement

MAINTENANCE
PERFORMANCE
TESTS
The
UUT
settings in
this
procedure
are
chosen
to
provide a strong confidence of
the
modulation performance
of
the
UUT
throughout
its
range.
However, performance
also
may
be checked
at
other instrument
settings
if
desired.
The
FM
deviation
accuracy depends
upon
software correction data stored
in
the
VCO
Calibration
EPROM
that
is
derived
from
the
measured
data of
the particular
VCO
assembly
installed in
the
Generator.
TEST
EQUIPMENT
Modulation Analyzer
Distortion
Analyzer
Frequency Counter
Low-Frequency
Synthesized Signal
Generator
(LFSSG)
DVM
PROCEDURE
1.
Internal
Modulation
Oscillator
Frequency
Test
a.
Connect
the
UUT RF OUTPUT
to the
Modulation Analyzer
input,
b.
Connect
the
Modulation Analyzer modulation
output
to the
Frequency
Counter
input.
c.
Program
the
Modulation
Analyzer
to
measure
AM
depth
in
a 0.05-kHz
to
15-kHz
bandwidth.
d.
Program
the
UUT
to
[RCL]
[9][8].
Program
the
UUT
for
90% INT
AM
at
a
1-kHz
rate
and
a
level
of
+1 dBm.
e.
Verify
that the
Counter
reads
between 970 and 1030 kHz.
f.
Program
that the
UUT
to
a
modulation
frequency of
400
Hz.
g.
Verify the
Counter
reads
between 388
Hz
and 412
Hz.
2.
Internal
AM
Accuracy
Test
a.
Measure
the
mean
AM
depth,
(+PEAK
plus
-PEAK)/2,
with
the
Modulation
Analyzer.
b.
Verify
that the
mean
AM
depth
is
between
84.4% and
95.6%.
c.
Program
the
UUT
to
a
modulation
frequency of
1
kHz.
d.
Verify that the
mean
AM
depth
is
between
84.4% and
95.6%.
3.
AM
Accuracy and
Distortion Test
a.
Connect
the
output of
the
LFSSG
to the
UUT
MOD
INPUT
and
the
DVM
(use
a
BNC T
connector).
b.
Program
the
U
UT
for
a frequency of
0.4
M
Hz,
1
d
Bm
level,
and
EXT A
M
at
30%
AM
depth.
4A-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents