Service Manual
PVG 32 Proportional Valve Group
PVG 32 Component Troubleshooting
PVAS module
Failure mode
Leaking externally between
sections
36 |
©
Danfoss | February 2017
PVPVM module
Do not try to adjust
or disassenmble PVLP
Description: Tie rod kit.
Location: Through the valve stack.
Function: Holds the stack together.
Cause
Tie rods under torqued
Tie rods torque too tight
13 mm
40 Nm
[354 lbf•in]
Plug
P107 808E
Corrective action
Check and retorque - 28 Nm [248 lbf•in]
Replace and retorque - 28 Nm [248 lbf•in]
11039167 | AX00000031en-US0301