Danfoss PVG 32 Service Manual page 4

Proportional valve group
Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

Service Manual
PVG 32 Proportional Valve Group
Contents
4 |
©
Danfoss | February 2017
PVEM, PVEA, PVEH, PVES electrical actuators...................................................................................................................... 38
Troubleshooting Considerations..............................................................................................................................................38
PVEO ON/OFF electrical actuator............................................................................................................................................. 39
PVPC plug for external pilot control........................................................................................................................................42
PVMR Friction Module..................................................................................................................................................................42
11039167 | AX00000031en-US0301

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVG 32 and is the answer not in the manual?

Questions and answers

Александр
March 5, 2025

После нескольких поворотов катка гидравлика уходит в аварию при перезагрузке снова срабатывает несколько раз и останавливается в аварии.

1 comments:
Mr. Anderson
March 5, 2025

The Danfoss PVG 32 hydraulic system could go into fault mode after several turns of the roller due to the following possible causes:

1. Contamination in Hydraulic Oil – Dirt or debris in the oil can affect valve operation.
*Check*: Take an oil sample.
*Corrective Action*: Flush the system and refill with clean, filtered fluid per OEM specifications.

2. Air in Hydraulic Pilot Lines – Air trapped in the signal lines can cause unstable operation.
*Check*: Inspect for air in the signal lines.
*Corrective Action*: Bleed air from the hose connection at the valve section.

3. Low Hydraulic Oil Supply – Insufficient oil can cause pressure drops and improper function.
*Check*: Verify fluid level in the reservoir.
*Corrective Action*: Refill with clean, filtered fluid per OEM specifications.

4. Faulty Hydraulic Remote Actuator – A malfunctioning actuator can lead to inconsistent valve response.
*Check*: Measure signal pressure from the remote hydraulic controller.
*Corrective Action*: Repair or replace the actuator.

5. External Hydraulic Pilot Pressure Too Low – If pressure is too low, the main spool may not function properly.
*Check*: Measure external pilot pressure from the pilot pump and check for restrictions.
*Corrective Action*: Ensure the pilot pressure meets the required specifications.

6. Leaking or Burst Supply Hose – A damaged hose can lead to pressure loss and system faults.
*Check*: Inspect supply lines to the valve stack.
*Corrective Action*: Repair or replace damaged hoses.

These potential causes should be systematically checked and corrected to restore proper system operation.