Service Manual
PVG 100 Component Troubleshooting
PVAS Module
Failure mode
Leaking externally between sections
34
PVG 100 Proportional Valves
PVLP, PVLA plugs
PVTI
PVLP
13 mm
40 Nm
[354 lbf•in]
For specifications and operating parameters on PVG 100 valves, refer to PVG 100 Technical Information
Manual 520L0720.
Description: Tie rod kit.
Location: Through the valve stack.
Function: Holds the stack together.
Cause
Tie rods under torqued
Tie rods torque too tight
11048807 • Rev BA • October 2014
PVT
PVLA
P107 849
Corrective action
Check and retorque - 38-42 Nm [28-31 lbf•ft]