3.5.5 FUNCTION 5: SETUP PROFILES

This function is used to load profiles into the 6600 from a PC. A full explanation of how to
load profiles into the 6600 is provided in Section 4.. The following screen will come up when
Function 5 is selected.
Once the profiles have been loaded, press GO to exit this function.

3.5.6 FUNCTION 6: HEIGHT CORRECTION

This function allows the user to enter the difference in height between the 6600 and Ground
level. This value should normally be 0 unless the 6600 is elevated to a height of more than 3
feet above ground level. A value of between 0 and 50 feet can be entered. The screen appears
as shown below.
Current Height Correction = 0 feet
New Height Correction
Enter new height (0-50) or press CANCEL

3.5.7 FUNCTION 7: SET GROUND

The "Set Ground" function is used to indicate to the 6600 the ambient "Ground" pressure.
Before connecting the 6600 to the aircraft, just after the Self Test has been performed, it is
mandatory that this function be invoked. All three ports (Pt, Ps1 and Ps2) must still be open
to ambient when using this function. When the "GO" key is pressed in the screen shown
below, the 6600 will "memorize" the ambient pressure it measures, as the "Ground" pressure.
This will be used later when the "Go To Ground" function is invoked.
Press "GO" to Set Ground ;
or press "CANCEL" to exit.
When the GO key is pressed, the 6600 responds with "Thank You" as an indication that
Ground has been set. It will then return to the Main screen. If the CANCEL key is pressed
the display will simply revert back to the Main screen.
PROFILE SETUP
Please stay in this screen and download
One or more profiles through the RS232
interface. On completion press "GO".
=
feet
46