Manual Pulse Generator Input Selection [Bfm #529]; 11.4.20 Ring Operation Rotation Direction For Absolute Address - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.4.19 Manual pulse generator input selection [BFM #529]

Sets the MPG input selection (Ver.1.10 or later)
BFM Number
X-axis
BFM
#529

11.4.20 Ring operation rotation direction for absolute address

Sets the rotation direction when absolute address is specified in the ring operation. (Ver.1.10 or later)
BFM Number
X-axis
BFM
BFM
#530
#630
154
→ For details on the manual pulse generator, refer to Section 8.3
Y-axis
0: X input - X opr / Y input -Y opr
-
1: X input / Y opr
2: X input - X and Y opr
Y-axis
0: Direction for shorter rotation
1: Direction where the current value increases (clockwise)
2: Direction where the current value decreases (counterclockwise)
11 Buffer Memory (Parameters & Monitored Data)
Description
→ For details on the ring counter setting, refer to Section 7.7
Description
11.4 Control Data
Default
K0
Default
K0

Advertisement

Table of Contents
loading

Table of Contents