FX
-20SSC-H Positioning Block User's Manual
3U
11.4.3 Target address 2 [BFM #505, #504, BFM #605, #604]
This data item sets a target position or travel distance for the positioning operation distance as the target
address 2.
BFM Number
X-axis
Y-axis
BFM
BFM
#505,#504
#605,#604
*1.
Refer to the section shown below for details on the user units.
Note
• The positioning operation differs as follows depending on the procedure to specify the absolute address or
relative address.
- With absolute address: travels from the current position to the target position.
The rotation direction depends on whether target address 2 is larger or smaller than the current address.
- With relative address: moves by the specified travel distance from the current position. The rotation
direction depends on the target address sign (+/-).
• The units of the value are user-specified and include the position data magnification.
11.4.4 Operation speed 2 [BFM #507, #506, BFM #607, #606]
This data item sets the operation speed 2 for positioning operations.
BFM Number
X-axis
Y-axis
BFM
BFM
#507,#506
#607,#606
*1.
Refer to the section shown below for details on the user units.
*2.
-2,147,483,648 to 2,147,483,647 with Variable Speed operation.
Note
• Set the operation speed 2 lower than the maximum speed.
If the operation speed 2 exceeds the maximum speed, the 20SSC-H operates at the maximum speed.
• You can change the operation speed during positioning operation if changing speed is enabled (when not
setting the flag for "speed change disable during operation").
11.4.5 Override setting [BFM #508, BFM #608]
This data item sets an override value for the override function.
BFM Number
X-axis
Y-axis
BFM #508
BFM #608
11.4.6 Torque output setting value [BFM #510, BFM #610]
This data item sets an output torque for the torque limit function.
BFM Number
X-axis
Y-axis
BFM #510
BFM #610
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
Set the value within -2,147,483,648 to 2,147,483,647 PLS in the converted pulse data
Setting range: 1 to 2,147,483,647 [User unit]
Set the value within 1 to 50,000,000 Hz in converted pulse data.
→ For details on the operation speed change function, refer to Subsection 7.6.2
→ For details on the override function, refer to Subsection 7.6.1
Setting range: 1 to 30000 (× 0.1%)
→ For details on the torque limit function, refer to Subsection 7.8.3
Setting range: 0 to 10000 (× 0.1%)
11 Buffer Memory (Parameters & Monitored Data)
Description
*1
Description
*1 *2
Description
Description
11.4 Control Data
Default
K0
→ Refer to Section 7.9
Default
K1
→ Refer to Section 7.9
Default
K1000
Default
K0
147
11
12
13
A
B