Deceleration Time [Bfm #14020, Bfm #14220]; Interpolation Time Constant [Bfm #14022, Bfm #14222]; Zero Return Speed (High Speed) [Bfm #14025, #14024, Bfm #14225, #14224] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.1.9 Deceleration time [BFM #14020, BFM #14220]

This parameter sets the time for the operation speed to reach zero from the maximum.
BFM Number
X-axis
Y-axis
BFM #14020
BFM #14220
Note
• The acceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when set at 5001
ms or more.
• Set the time within the range from 64 (greater than 64) to 5000 ms in the approximate S-shaped
acceleration/deceleration.

11.1.10 Interpolation time constant [BFM #14022, BFM #14222]

This parameter sets the time to reach the operation speed from zero (acceleration) or to reach zero from the
operation speed (deceleration).
BFM Number
X-axis
Y-axis
BFM #14022
BFM #14222
Note
The acceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when set at 5001 ms
or more.

11.1.11 Zero return speed (High Speed) [BFM #14025, #14024, BFM #14225, #14224]

This parameter sets the mechanical zero return operation speed (high speed) [DOG, Stopper #1].
BFM Number
X-axis
Y-axis
BFM
BFM
#14025,
#14225,
#14024
#14224
*1.
Refer to the section shown below for details on the user units and converted pulse data.
Note
• Set the zero return speed (high speed) at or below the maximum speed.
When the zero return speed (high speed) exceeds the maximum speed, the 20SSC-H operates at the
maximum speed.
• Speed change commands in positioning operation change the zero return speed (high speed) into a preset
value.
→ For details on the deceleration time, refer to Section 7.2
Setting range: 1 to 5000 ms
→ For details on the interpolation time constant, refer to Section 7.2
Setting range: 1 to 5000 ms
→ For details on the mechanical zero return, refer to Section 8.1
Setting range: 1 to 2,147,483,647 (user unit)
Set the value within 1 to 50,000,000Hz in converted pulse data
11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
Description
Description
Description
*1
*1
.
Default
K200
Default
K100
Default
K4,000,000
→ Refer to Section 7.9
123
11
12
13
A
B

Advertisement

Table of Contents
loading