Verify that the system software is compatible with the switching fabric module. Upgrade the
2.
system software if it is not compatible with the switching fabric module.
Calculate the total power consumption, and make sure your power supplies can provide
3.
enough power. For more information, see
Remove and reinstall the switching fabric module to make sure the module is installed securely.
4.
You also need to verify that the ejector levers are locked securely in place. For more information,
see
"Installing
If the switch has empty switching fabric module slots, install the module in an empty switching
5.
fabric module slot. If the module operates correctly, the previous slot is faulty.
If the problem persists, contract Hewlett Packard Enterprise Support.
6.

Interface failure

Symptom
The LED for the interface is off.
NOTE:
A management Ethernet port has two LEDs, LINK and ACT. When the LINK LED is off, the
management Ethernet port fails.
Solution
To resolve the problem:
Make sure the MPU or LPU where the interface resides operates correctly. For more
1.
information, see
Verify that the cable is connected correctly. For how to correctly connect a cable, see
2.
"Connecting your switch to the
Verify that the cable is in good condition. Use the cable to connect two interfaces of the same
3.
type that operate correctly. If the LEDs of the two interfaces are on, the cable is in good
condition. Otherwise, the cable is faulty. Use a compliant cable to connect the interface. For
more information, see
If the interface uses a transceiver module, perform the following tasks:
4.
a. Make sure the interface type is compatible with the transceiver and that the transceiver is
compatible with the cable. For more information, see
matrixes."
b. Replace the transceiver module.
Verify that the speed and duplex settings of the interfaces on the two ends are the same.
5.
If the problem persists, contact Hewlett Packard Enterprise Support.
6.
NOTE:
• If an interface is brought down by the shutdown command, use the undo shutdown
command to bring up the interface.
• After an interface fails, if the switch has an idle interface of the same type, you can connect
the cable to the idle interface.
Technical support
Before contacting Hewlett Packard Enterprise Support, prepare the following information: