4--1 Block Diagram; 4--2 D/A Conversion - Omron SYSMAC C2000H Operation Manual

Analog i/o units
Hide thumbs Also See for SYSMAC C2000H:
Table of Contents

Advertisement

4--4--1
Block Diagram
Point
+
1
Voltage output
_
Analog 0 V
+
Current output
_
Point
+
2
Voltage output
_
Analog 0 V
+
Current output
_
The current outputs are not connected in Modules whose voltage output range is other than 1 to 5 V.
4--4--2
D/A Conversion
Unipolar Outputs
The following diagram shows the basic internal connections of the Module.
D/A
Ranger selector
D/A
Analog power supply
These Modules convert 12-bit binary data to voltage or current output. Each
Module has a different type of output. Outputs can be either unipolar or bipo-
lar, with the resolution depending on the model.
Output ranges: 0 to 10 V, 0 to 5 V, or 1 to 5 V (4 to 20 mA)
Data format:
12-bit binary
Data conversion for unipolar outputs is illustrated below.
Photo-
Memory
coupler
Photo-
Memory
coupler
Photo-
coupler
DC/DC converter
Section 4--4
PLC
Bus
I/O
interface
bus
Timing
circuit
5 V
0 V

Hide quick links: