Updating Me Firmware - Intel R1304BTSSFAN Service Manual

Table of Contents

Advertisement

update utility may generate an error stating the Integrated BMC is still in
update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.

Updating ME Firmware

When performing the standard ME force update procedure, the update utility places the
ME into an update mode, allowing the ME to load safely onto the flash device. In the
unlikely event ME firmware update process fails due to ME not being in the proper update
state, the server board provides an Integrated BMC Force Update jumper, which forces the
ME into the proper update state. The following procedure should be completed in the
event the standard ME firmware update process fails.
1. Power down and remove the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper from the default operating position (covering pins 1 and 2) to the
enabled position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the ME firmware update procedure as documented in the README.TXT
file that is included in the given ME firmware update package (same package
as BIOS).
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
®
Intel
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Service Guide
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1304btlsfanR1304btlshbn

Table of Contents